Description
 The glassbreak-detector is keeping a plane glass-area within a maximum radius of 2 m under
surveillance.
 Oscillations of glassbreak, which are not reaching the glassbreak-detector with the sufficient
amplitude and frequency, can't be detected.
 To see a later loosing off, the glassbreak-detector should be pasted horizontal at the panel of
glass with 5 mm distance to the frame.
 On one side the distance to the frame must be 20 mm. At the side, where the cable leaves the
glassbreak-detector, you can choose a distance between 5 and 20 mm to the frame.
 A surveillance of structure-glass is not possible. Also it is not allowed to use the glassbreak-
detector on wired glass or security-glass, because the wire netting and the plastic-foil are
damping the mechanical oscillations.
 It is important, that the pane of glass is in an unobjectionable condition, without any cracks
(possibility for false alarm), proper fixed in the frame and not pasted with any foils.
Caution: The glassbreak-detector is highly sensitive. Knocking at the glassbreak-detector or
other improper treatment could cause in the destruction of the glassbreak-detector.
 The glassbreak-detector must be pasted at the pane of glass with the adhesive set included or with
glueset from LOCTITE 319 (not included) for more trustworthiness. Please follow the handling
instructions of the manufacturer.
 The housing-bottom (ceramic substrate) of the glassbreak-detector and the joint-area must be cleaned
and degreased with spirit, methylalcohol or with the cleaning towels GMS R 1 (look at specifications).
Important: Each alien element which is between the bottom of the glassbreak-detector and the pane
of glass will affect the sensibility.
 The function of the glassbreak-detector can be tested after the installation with the test-set RT03.

TECHNICAL SPECIFICATIONS

Electronic switch ( NO contact ), also suitable for wireless alarm systems.
Surface Mount Technology.
Housing base:. ................................................................................................... ceramic substrate
Power consumption: ............................................................................................................... 0 mA
Switching voltage: ......................................................................................................... max 18Vdc
Switching current .......................................................................................................... max 10 mA
Contact capacity: ...................................................................................................... max. 350 mW
Transition resistance
quiescent state: .......................................................................................................... max. 30 ohm
alarm state:................................................................................................................... min. 1 ohm
Alarm duration ............................................................................. 0,5/5 s (according to glassbreak)
Effect radius: ..................................................................................................................... app 2 m
Connecting cable: ..................................................................... LIYY ZGL 2 x 0,14 mm² Cu tinned;
suitable for insulation displacement technology LSA-PLUS
Inner conductor: ..................................................................................................................... white
Cable dimensions: ................................................................................................. L2 m, Ø 3,2 mm
Housing dimensions: ............................................................................................ 37 x 19 x 12 mm
Housing material:...................................................................................................................... S-B
Colour:.................................................................................................................................... white
Operating temperature: .................................................................................. from -25°C to + 70°C
Protection category: ................................................................. VdS - environmental class IV; IP 67
Options:
 Glassbreak detector adhesive set (included)
 Glassbreak detector tester RT03 (not included)
 Glassbreak detector glueing guide KF-GD (not included)
GD05PL