Technical Features; Notes Concerning En50131-4 Certification - Elkron HP375M Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TECHNICAL FEATURES

Rated supply voltage..............................................................................14,4 Vdc
Operating voltage...................................................................................13,8 Vdc ÷ 15 Vdc
Battery operation minimum and maximum voltage ................................10,5 Vdc ÷ 13,8 Vdc
Standby current sink ..............................................................................3 mA @ 12 Vdc
Max current in alarm ..............................................................................2,2 A (power tone)
Max ripple allowed .................................................................................500 mV
Acoustic pressure (power tone) .............................................................116 ± 1 dB (A) @ 1 m
Working frequency .................................................................................1700 Hz (intermittent tone AL2)
AL1, AL2 and S blocking signal inputs (ref. to positive) .........................7,3 Vdc
AL1, AL2 and S blocking signal inputs (ref. to negative)........................4,8 Vdc
Current sink of AL1, AL2 and S inputs ...................................................2 mA
Max central unit absorption ....................................................................150 mA
Anti-opening/anti-removal micro-switch .................................................1 A @ 24 Vdc
Operating temperature certified .............................................................-25°C ÷ +55°C
Max permitted humidity ..........................................................................93%
Environmental class ...............................................................................II
EN50131-4 certification..........................................................................Grade 2
Case protection degree..........................................................................IP30 / IK06
Case.......................................................................................................steel zinc plated and painted
Anti-tamper protection............................................................................opening and removing
Compatible accumulator type.................................................................12V from 2 to 2,2 Ah
Internal battery autonomy in stand-by condition.....................................> 36 hours
Internal battery autonomy in alarm condition .........................................>30 minutes
Type of connecting cable .......................................................................3-pair shielded cable (0,22mm
Dimensions (w x h x d) ...........................................................................195x180x55 mm
Weight (without battery) .........................................................................1300 g

NOTES CONCERNING EN50131-4 CERTIFICATION

Importantly, jumper C must be kept intact to allow the siren to sound in case of remote power blackout for
the compliance to EN50131-4. Cutting this jumper will cause loss of compliance.
The intermittent sound (control AL2) is an auxiliary signal (it must not be used for burglar and/or tamper
alarm indications).
Note:
The batteries are considered dangerous waste (E.W.C.
160601) and they must be given to an authorised waste
disposal.
2000-3000 Hz (power tone)
16/24
2
)
HP375M

Publicité

Table des Matières
loading

Table des Matières