Technical Characteristics - Elkron HPA700M Notice D'installation

Masquer les pouces Voir aussi pour HPA700M:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8.0 TECHNICAL CHARACTERISTICS

Sound alarm device type ...................................................................... Z
Rated supply voltage............................................................................ 13.8 Vdc, 14.4 Vdc
Operating voltage with double-balanced inputs to positive. .................. 9 ÷ 14,0 Vcc
Operating voltage with NC inputs to negative ....................................... 9 ÷ 15 Vdc
Absorption at rest ................................................................................. 7 mA
Max alarm absorption ........................................................................... 1600 mA medium; 2500 mA peak
Flash absorption .................................................................................. 6 mA medium; 60 mA peak
Protection module absorption ............................................................... 6 mA
Max control unit absorption .................................................................. 150 mA
Acoustic pressure ................................................................................ > 107 dB (A) @ 1 m
Operating frequency ............................................................................ 1400 ÷ 1600 Hz
Sound timeout ...................................................................................... 15 minutes
Flash light colour .................................................................................. orange
Flash light blinking frequency ............................................................... 1 Hz
Input lock voltage (NC to positive) ........................................................ >4.3 Vdc
Input lock voltage (double-balanced to positive) ................................... 5.1 ÷ 8.7 Vdc
Input activation voltage (double-balanced to positive) .......................... 2.3 ÷ 5.0 Vdc
Control input absorption ....................................................................... 1 mA (double-balanced); 2.2 mA (NC)
Operating range with internal battery on standby ................................. 60 hours
Low battery threshold ........................................................................... 11.5 Vdc
Out of battery threshold ........................................................................ 10 Vdc
Siren tamper contact (solid state relay) ................................................ 50 mA @ 50 Vdc; R typ = 20 Ω
Protection module tamper contact (solid state relay) ............................ 50 mA @ 50 Vdc; R typ = 20 Ω
Environment Class ............................................................................... IV
Certified operating temperature ............................................................ -25 °C ÷ +70°C
Max permitted humidity ........................................................................ 93%
Certified enclosure protection degree ................................................... IP44 / IK08
External cover material ........................................................................ die-cast aluminium
Flash cover material ...................................................................................... Self-extinguishing PC-ABS
Optional internal cage material ............................................................. zinc-coated 8/10 sheet
Bottom material .................................................................................... Self-extinguishing PC-ABS
Allocable battery .................................................................................. 12V – 1.9 to 2,2Ah
Dimensions (w x h x d) ......................................................................... 203 x 253 x 87 mm
Weight (without battery) ....................................................................... 1500 g
Connection cable ................................................................................. 6 0.22 mm
Tamper ................................................................................................ Opening and removal
Guaranteed performance level (EN50131-4) ........................................ Grade 3
) The 14.4V voltage supplied by a number of control units for internal battery charging CANNOT be
*
used with double-balancing inputs referred to positive.
HPA700M
Compliant with standard : EN50131-4
Rating: Grade 3
Certificate no.: 3230900011
IMPORTANT: Batteries must be deemed dangerous wastes
(E.W.C. 160601) and therefore they must be delivered to
authorised disposal operators.
32/44
*
wires + 2 ≥0.50 mm
2
2
wires
HPA700M

Publicité

Table des Matières
loading

Table des Matières