Connections; Configurations - Elkron HP375M Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CONNECTIONS

TA
Anti-Tamper micro-switch supporting
terminal
TA
S
System status input
AL1
Alarm control input
+
To power supply positive
-
To power supply negative
AL2
Signalling unit control input
Positive battery (connected at the
+B
factory)
Negative battery (connected at the
-B
factory)
AP
Horn connecting terminals
(connected at the factory)
AP
Use screened multipole cable for burglar alarm systems.
WARNING: THE BATTERY INSIDE THE SIREN MUST BE USED given the limited current drawn by the
control panel.

CONFIGURATIONS

The siren is configured by means of wire jumpers, apart from the ringing level related to the AL2 command
that is set using the jumper (Liv. audio). The jumpers functions are listed (factory setting in block letters):
IDENTIFICATION
A - B
C
D
E
F
IDENTIFICATION
Liv. audio
WARNING:
Cutting the jumper C will affect compliance with the standard
FUNCTION
Timeout ringing lock
EN functionality
AL1, AL2 and S
inputs references
Alarms counting
AL2 Input
FUNCTION
AL2 Sound Level
CLOSED
A closed – B closed = 15 min
A closed – B open = 9 min
A open – B closed = 6 min
A open – B open = 3 min
No power supply
acoustic alarm
To positive
Deactive
AL2 not used
CLOSED
High level
EN50131-4.
14/24
TO THE BATTERY
OPEN
No acoustic alarm
for no power supply
To negative
Active
AL2 active
OPEN
Low level
HP375M