TAMPER :
Supporting terminals for connect anti-opening/anti-removal limit switch wires leading to control unit
24h input.
TC1:
Flasher block input. TC reference from control unit can be positive or negative.
BL1:
Control block input referred to positive or negative.
:
Module power positive.
+
- :
Power negative
+FLASH- :
Flasher connection.
SPEAKER:
Speaker connection.

3.1 FOAM PROTECTION DEVICE CONNECTION (HP602LG)

Power the device by connecting the black wire to negative power
supply of siren unit. Red wire is already connected by the factory to
the positive of flash.
Tamper terminale block is the N.C. alarm ouput of the protection
module. Provide a series connection in the tamper line (as shown in 6.0).
12

3 CONNECTIONS

HP602L-HP602LG