Connections; Configurations - Elkron HP305 Manuel D'installation

Sirène intérieure auto-alimentée de puissance à double fonction
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CONNECTIONS

TAMPER

CONFIGURATIONS

The siren is configured by means of wire jumpers, apart from the ringing level and the power set-up that is set
using the jumpers (JP2 and JP6). The jumpers functions are listed (factory programming in block letters):
IDENTIFICATION
JP1
JP2
JP3-JP4
JP5
IDENTIFICATION
JP6
(1)
For HP305P version the battery is mandatory.
JP1 JP2 JP3 JP4
JP5
TAMPER TC1
BL1
+
Connecting anti-tamper micro-switch
TC1
TC input
BL1
BL1 input
+
To power supply positive
-
To power supply negative
BL2 input
BL2
FUNCTION
Input BL2
BL2 Sound Level
Timeout ringing lock
BL1, BL2 and TC
inputs references
FUNCTION
Siren power-up
3
2
JP6
1
+
_
_
BL2
TO THE BATTERY
CLOSED
BL2 not used
High level
JP3 closed – JP4 closed = 30 min
JP3 open – JP4 closed = 9 min
JP3 closed– JP4 open = 6 min
JP3 open – JP4 open = 3 min
To positive
(1)
POSITION 1-2
With battery
(Self powered siren)
14/16
OPEN
BL2 active
Low level
To negative
POSITION 2-3
Only from Control Panel
(without self power)
HP305 / HP305P

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hp305p

Table des Matières