Télécharger Imprimer la page

RIB KING Instructions Pour L'utilisation Et L'installation page 21

Publicité

Les langues disponibles

Les langues disponibles

Fig. 2
PRE-INSTALLATION CHECKS
The leaf must be fixed firmily on the hinges to the pillars, must not be flexible during the
movement and must move without frictions.
Before the installation of KING, verify all dimensions etc.
There's no need for any modification, if the gate is like that shown in Fig. 2.
Gate features must be uniformed with the standards and laws in force. The gate can
be automated only if it is in a good condition and its conditions comply with the EN 12604
norm.
- The gate leaf does not have to have a pedestrian opening. In the opposite case it is
necessary to take the appropriate steps, in accordance with EN 12453 norm (for
instance; by preventing the operation of the motor when the pedestrian opening is
opened, by installing a safety microswitch connected with the control panel).
- No mechanical stop shall be on top of the gate, since mechanical stops are not safe
enough.
TECHNICAL CHARACTERISTICS OF THE OPERATOR
KING is a series of linear irreversible operators, suitable for opening gates with a leaf
length of up to 4,5 metres (Fig.2).
The KING operators use mechanical stoppers, thus avoiding the need for electrical limit
switches.
On reaching the travel limit, the motor continues to operate for a few seconds, until the
timer of the control unit (or the ENCODER in the PLUS version) cuts in.
Parts to install meeting the EN 12453 standard
COMMAND TYPE
with manned operation
with visible impulses (e.g. sensor)
with not visible impulses
(e.g. remote control device)
automatic
* a typical example are those shutters which do not have access to any public way
A: Command button with manned operation (that is, operating as long as activated), like code ACG2013
B: Key selector with manned operation, like code ACG1010
C: Adjustable power of the motor
D: Safety edges, like code ACG3010 and/or other safety devices to keep thrust force within the limits
of EN12453 regulation - Appendix A.
E: Photocells, like code ACG8026 (To apply every 60÷70cm for all the height of the column of the
gate up to a maximum of 2,5m - EN 12445 point 7.3.2.1)
USE OF THE SHUTTER
Skilled persons
Skilled persons Unrestricted use
(out of a public area*)
(public area)
A
B
C or E
C or E
C or E
C and D, or E
C and D, or E
C and D, or E
SYSTEM LAY-OUT
KING operator
Tuned aerial
Flashing lamp
Key selector
Photoelectric cells (external)
TECHNICAL
DATA
Max. leaf length
Max. leaf weight
Max. travel
Average opening time
Operating speed
Thrust force
EEC Power supply
Motor capacity
Power absorbed
Capacitor
Power supply
Motor capacity
Power absorbed
Capacitor
Power supply
Motor capacity
Power absorbed
Capacitor
No. normative cycles 230V
No. normative cycles 220V
No. normative cycles 120V
No. of daily operations suggested
Service
No. guaranteed consecutive cycles
not possible
C and D, or E
Grease
C and D, or E
Weight of electroreducer
C and D, or E
Noise
Volume
Protection
** With incorporated mechanical stop that cuts in during opening. - If the
mechanical stop is used during closing (optional), the maximum travel is
reduced by 50 mm.
Pag. 21 di 40
KING
KING L
m.
3,5*
4,5*
kg
400
500
mm
345**
475**
s.
14÷27
29÷38
m/sec.
0,0125
N
1400
230V~ 50Hz
W
290
A
1,2
µF
10
220V~ 60Hz
W
225
A
1,04
µF
8
120V~ 60Hz
W
255
A
2,3
µF
35
n° 17 - 14s/2s
10 - 33s/2s
n° 31 - 14s/2s
20 - 33s/2s
n° 29 - 14s/2s
11 - 33s/2s
150
60%
20/14s
15/33s
Bechem - RHUS 550
Kg
10
14
db
<70
m
0,0184
0,0211
3
IP
447
E
N
G
L
I
S
H

Publicité

loading