Service Mode For Rls 45 Rc - Maico PushPull PP 45 O Notice D'installation

Masquer les pouces Voir aussi pour PushPull PP 45 O:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

14.4 Service mode for RLS 45 RC

PP 45 RC LEDs
The orange operating
mode LED flashes
once per cycle
The orange operating
mode LED flashes
twice per cycle
The orange operating
mode LED flashes
three times per cycle
The blue operating
mode LED flashes
once per cycle
The blue operating
mode LED flashes
twice per cycle
The blue operating
mode LED flashes
three times per cycle
Parameter
Setting
Exhaust air
0
mode
1
2
Sensor
0
1
Ventilation
0
level "0"
1
(off)
Duration of
1
ventilation
2
level
3
Rest period
1
2
3
Filter runtime 1
2
3
4
14 Service mode | UK
bold = factory setting
Setting
Exhaust air mode without
overrun
Exhaust air mode with overrun of
6 min. (red LED once)
Exhaust air mode with overrun of
15 min. (red LED twice)
Inactive
active (red LED once)
Ventilation level "0" possible
Ventilation level "0" blocked
(red LED once)
10 minutes (red LED once)
30 minutes (red LED twice)
60 minutes (red LED three times)
30 minutes (red LED once)
60 minutes (red LED twice)
90 minutes (red LED three times)
2 months (red LED once)
3 months (red LED twice)
6 months (red LED three times)
Reset filter runtime (red LED four
times)
87