Produktgruppe 512
59 von 60
WRG02 Water Recycling Assembly Installation:
Tank installation:
Warning!
Before starting work, ensure that the wall is strong enough to support the load. The tank weight is approx. 200 kg.
Note
Use the holder frame as a template.
Take the required measurements from the appropriate installation plan.
Drill 10 mm dia. holes.
Warning!
Pay attention to different height measurements!
Note
The hardware supplied can be used for concrete
For other types of wall, suitable hardware must be provided on site.
Screw two M 6 x 16 bolts into the top mounting nuts.
Hang the tank in the top mounting holes.
Screw in the remaining bolts (6 x) and tighten them.
Secure the hoses on the container lid with 32 - 50 mm dia. hose clips; see Fig. 19.
Insert the hose connectors (Fig. 19, Pos. 1) into the angled hoses and secure with 32 - 50 mm dia. hose clips.
Warning!
Pay attention to the positioning of the vent hose!
Secure the connection hose to the drain valve on the tank with a 40 - 60 mm dia. hose clip.
Secure the angled drain hose to the drain valve with 40 - 60 mm dia. hose clip.
Filter assembly:
Connection to machine, see (Fig. 20, Pos. 1).
Note
The pipe (Fig. 20, Pos. 4) is not required with installation behind the machine.
For installation with WS 5240/5320 the pipe (Fig. 20, Pos. 4) must be installed between the elbow (Fig. 20, Pos. 2) and the bushing
(Fig. 20, Pos. 3).
Tank overflow connection, see Fig. 20, Pos. 5.
Connection to the on-site drainage system (DN 70), see Fig. 20, Pos. 6.
Connection from the immersion pump to the tank, see Fig. 20, Pos. 7.
16.12.2011
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
B 15 and undrilled wall tiles
MZ 15.
M.-Nr. 04598534