Figure 18. Accessing And Wiring To The - Zodiac AquaPure EI 1APURE35C Guide D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
Page 16
3.6.2
Wiring to the Aqualink
system or PDA
WARning
FOR YOuR sAFETY: This product must be
installed and serviced by a professional pool/spa
service technician as described on the front cover
of this manual. The procedures in this manual must
be followed exactly. Failure to follow warning notices
and instructions may result in property damage,
serious injury, or death. Improper installation and/or
operation will void the warranty.
When using electrical products, basic precautions
should always be followed, including the following:
• DANGER: RISK OF ELECTRIC SHOCK WHICH
CAN RESULT IN SERIOUS INJURY OR DEATH.
Before attempting installation or service, ensure
that all power to the device is disconnected/turned
off at the circuit breaker. Connect only to a circuit
protected by a ground-fault circuit-interrupter
(GFCI).
• Grounding is required. The unit should be serviced
by a qualified service representative and should
be properly grounded. (See Section 3.4, Wiring
the Power Pack to Power Source).
• Install to permit access for servicing.
Please read all cautions and safety instructions
in the Important Safety Instructions section.
Before attempting any electrical wiring, be
sure to read and follow safety instructions.
Wiring should only be attempted by a qualified
professional..
1.
Ensure that all power to the power pack and
the controller is disconnected/turned off at the
circuit breaker.
2.
Remove the screws attaching the cover to the
back plate and prop the cover up to expose the
terminals (see Figure 18).
nOTE Be careful not to pull the ribbon cable that is
connected to the Power Supply and the Cover.
3.
Remove the white cap covering the comm hole
(see Figure 18).
4.
Thread the controller cable through the hole. A
grommet may be necessary depending on the
size of the cable being used.
5.
Attach a cable tie to the controller cable as
shown (see Figure 18).
Zodiac
AquaPure
Ei Series APURE35C
®
®
®
Rs Control
|
Installation and Operation Manual
Prop the cover
on the two
posts located
on the back plate
Comm Hole
Figure 18. Accessing and Wiring to the Power PCB
6.
In the AquaLink
the power pack directly to the LOAD SIDE of
the filter pump relay (see Figure 19).
7.
The AquaLink
RS or PDA and power pack use
a four (4) wire connection to communicate and
can be wired up to 152.4 m (500 ft) apart. Any
outdoor rated four conductor cable, minimum
0.33 mm
(22 AWG), can be used. Locate the
2
appropriate screw terminals on the circuit board
and wire the power pack
PDA red 4-pin terminal bar (see Figure 20).
The screw terminals on the AquaLink RS or PDA are
nOTE
removable to aid in installation.
3.6.3
Testing the Connection
Once the power pack has been wired to the AquaLink
RS Control System or PDA, follow these steps to test
the connection:
1.
Apply power to the power pack and the
AquaLink RS Control System or PDA.
2.
Wait about 20 seconds. If the connection was
successful, a Ŧ symbol will appear in the top
right corner of the power pack display.
nOTE If the power pack does not connect to the controller,
turn the power off to both devices and repeat steps
1 and 2. If the power pack still does not connect to
the controller, re-check the wiring connections (see
Section 3.6.2) and the controller setting on the power
pack (see Section 3.6.1).
Cable Tie
RS or PDA power center, wire
to the AquaLink
RS or

Publicité

Chapitres

Table des Matières
loading

Table des Matières