Attach the third wire (ground) from the
electrical panel to the ground point inside the
power pack. Additionally, applicable local and/
or National installation codes may require the
equipment to be properly bonded to other pool
equipment or to a bonding grid. Bonding per
Section 3.5 must also be accomplished to ensure
personal safety and safety of equipment.
3.5

Bonding

Canadian Electric Code
(CEC) requires pool
®
equipment to be bonded to each other. Check your local
codes to determine if other local installation codes are
enforced by the Authority Having Jurisdiction (AHJ). A
solid, copper 13.3 mm
(6 AWG) wire is recommended,
2
per the CEC™, for bonding the power pack to a
permanent bonding connection that is acceptable to
the local AHJ. Refer to your locally enforced codes for
the acceptable bonding wire gauge. Attach the bonding
point located on the bottom of the chassis backplate to
a common bonding point. Do not use the power pack as
the common bonding point. Each piece of non-related
pool equipment requiring a ground should also be
bonded to the common, approved bonding point. There
should be one bonding connection to the power pack.
CEC™ dictates that the bonding conductor be minimum
13.3 mm
(6 AWG).
2
3.6
Connection to an Aqualink
Control System or PDA (Optional)
The AquaLink RS or PDA is a multi-function pool
controller which can fully control the function of
the Zodiac AquaPure Ei Series APURE35C chlorine
generating device. Adjustment of the chlorine
production rate can be controlled from the main menu
of the AquaLink RS or PDA. The AquaLink RS or
PDA offers individual pool and spa settings for output
percentage. Refer to the AquaLink RS or PDA Owner's
Manual for more information.
nOTE The Zodiac AquaPure Ei Series APURE35C chlorine
generating device will communicate with all AquaLink
models Rev. K or later.
AquaPure
Ei Series APURE35C
®
®
Rs
|
Installation and Operation Manual
3.6.1
Verify the Controller Type on the Power
Pack is set Correctly
Before wiring to an AquaLink RS Control System,
the controller type must be set to JANDY L/M to
allow communication between the power pack and the
AquaLink RS Control System. The default controller
setting on the power pack is JANDY L/M. Follow the
instructions below to verify the controller type is set
correctly.
nOTE The controller type must be set correctly before
making the wiring connection between the power
pack and the AquaLink, otherwise the power pack
may be locked out of the AquaLink.
To verify the controller type is set correctly:
1.
Apply power to the power pack.
2.
Wait for the start-up sequence to complete.
3.
Press and hold the OUTPUT button for
approximately four (4) seconds. After four (4)
seconds, a controller type will be displayed on
the screen.
4.
Verify that the JANDY L/M controller type
appears on the display. If the controller type
is not set to JANDY L/M, keep the OUTPUT
button pressed to toggle through the list of
controllers. Each controller will be displayed
on the screen for two (2) seconds. Release the
OUTPUT button when JANDY L/M appears on
the display.
Page 15
English

Publicité