Installing The Power Pack And Cell - Zodiac AquaPure EI 1APURE35C Guide D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Zodiac
®
3.3

installing the Power Pack and Cell

WARning
If you are installing the Zodiac AquaPure Ei Series
APURE35C to a Goldline
disconnect the power to the Goldline controller.
Zodiac recommends that any procedure requiring potential
contact with live electrical wiring and/or parts other
than cords and plugs connected to electrical outlets, be
completed by a contractor who is licensed and qualified
in pool equipment as described on the front cover of this
manual. Failure to follow warning notices and instructions
may result in property damage, serious injury, or death.
WARning
To avoid property damage, serious injury or death, do not
operate the electrolytic cell without water circulation. A
buildup of flammable gasses which can result in FIRE OR
EXPLOSION.
1.
Ensure placement of the cell and the power
pack will meet all the installation requirements
outlined in Section 3.2.
2.
Screw the power pack bracket into position on a
wall surface where it will mount securely, while
ensuring it is no more than 4.6 m (15 ft.) from
the cell (see Figure 4).
3.
Position the power pack in place by aligning the
bracket with the corresponding thru-holes (see
Figure 4).
Screws
Figure 4.
Attaching the Power Pack
* The Goldline brand is property of Hayward Industries, Inc. and/or its subsidiaries or affiliates. All other trademarks used herein are the property of their respective owners.
AquaPure
Ei Series APURE35C
®
adaptor, it is necessary to
®
Thru-holes
|
Installation and Operation Manual
4.
Wire the power pack to the LOAD side of the
pump or the LOAD side of the pool pump timer
relay so that the chlorinator can only come on
when the pool pump comes on (see Section
3.4). Attach the bonding wire and connect
it to a common bonding point (see Section
3.5). If available, wire the power pack to an
AquaLink® RS Control System or PDA (see
Section 3.6).
5.
Unscrew the locking ring from the cell in order
to extract it from the upper clamp
(see Figure 5).
Figure 5.
Disassemble Cell
6.
Press the two (2) push-buttons on either side
of the upper clamp to separate the upper clamp
from the lower clamp (see Figure 5).
7.
Invert the lower clamp and place on the pipe.
Mark the pipe for drilling the feeder holes (see
Figure 6).
The two holes in the
lower clamp serve as a
template for
the feeder holes.
Figure 6.
Marking Pipe for Drilling Feeder holes
English
Upper Clamp
with Gasket
Lower Clamp
Page 11