Bypass Plumbing Instructions: If Flow Rate Exceeds 348 L/Min (92 Gpm); Figure 19. Wiring Power Pack To An Aqualink ® Rs Or; Figure 20. Communication Wiring Between Power; Pack And Aqualink Rs Or Pda Power - Zodiac AquaPure EI 1APURE35C Guide D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Zodiac
Filter Pump Relay
To Filter Pump
(240 VAC)
Figure 19. Wiring Power Pack to an AquaLink RS or PDA Power Center (240 VAC and 120 VAC)
Red, 4-Pin
Terminal Bar
4 3 2 1
OPTIONAL
Power Center

Figure 20. Communication Wiring between Power

Pack and Aqualink Rs or PDA Power

Centre
AquaPure
Ei Series APURE35C
®
®
AquaLink
240 VAC
Aux. 3 Relay
To Breaker
Panel
Power Pack
GRN
YEL
BLK
RED
|
Installation and Operation Manual
RS or PDA Power Center
®
Filter Pump Relay
To Filter Pump
(120 VAC)
To Power Pack
(240 VAC)
3.7
Bypass Plumbing instructions: if
Flow Rate Exceeds 348 L/min (92
GPM)
If flow rate exceeds 348 L/min (92 gpm), the cell must be
plumbed on bypass otherwise it may result in property
damage, personal injury, or death.
nOTE Pool pumps greater than 2 HP may produce flow
rates exceeding 348 L/min (92 gpm). If you are
unsure of the flow rate of your pool pump, contact
your dealer for assistance.
The maximum flow rate for the cell is 348 L/min (92
gpm). If flow rate exceeds 348 L/min (92 gpm), the cell
MUST be plumbed on bypass (see Figure 21). A control
valve must be installed to regulate the flow through the
cell. It can be installed on the inlet side of the cell or
between the inlet and discharge side of the bypass piping.
The proper flow will be achieved by adjusting the handle
of the valve until the red "No Flow" light has turned off
and all large air bubbles are cleared from the cell.
Page 17
English
120 VAC
Aux. 3 Relay
To Power Pack
To Breaker
Panel
WARning
(120 VAC)