Section 3. Installation Instructions

WARNING
FOR YOUR SAFETY: This product must be installed
and serviced by a professional pool/spa service
technician, as described on the front cover of this
manual. The procedures in this manual must be
followed exactly. Failure to follow warning notices
and instructions may result in property damage,
serious injury, or death. Improper installation and/or
operation will void the warranty.
WARNING
EQUIPMENT UNDER PRESSURE
pump off prior to installing or servicing the Nature
Fusion. Your pump/filter system is operated under
pressure and the pressure must be released before
you begin work. Please see your pump/filter owner's
manual for further instructions.
3.1

Materials and Tools

Materials Furnished for Installation
Nature
Fusion Vessel with 5 - 6.3 cm (2"-2½") Universal
2
Unions
Installation and Operation Manual
Tools Needed for Installation
Tape Measure
Phillips & Flathead Screwdrivers
Pliers
Hacksaw
An NSF
approved All Purpose Cleaner Primer
®
An NSF approved All Purpose Cement
(such as Weld-On
794, 793)
®
3.2

Installation Requirements

Decide where to install the Nature
The vessel must be installed on a 43 cm (17")
length of pipe.
The vessel must be installed on the existing pad or a
concrete slab to support the weight.
The vessel must be installed as the last piece of
equipment in the circulation plumbing system just
before the pool with the Nature
and the chlorine side as the outlet.
The vessel must be installed downstream from the
heater or heater damage may occur.
Zodiac
Nature
Fusion Inground
®
: Always turn
2
Fusion vessel.
2
2
side as the inlet
|
Installation and Operation Manual
If the vessel is installed below the pool water
level, it must be installed with a check valve. The
check valve will isolate the vessel and prevent pool
draining during installation, cartridge change, or
chlorine tablet addition.
If plumbing size is greater than 5 cm (2") diameter
or if flow rates are greater than 455 lpm (120
gpm), the vessel must be installed in a bypass
configuration (see Section 3.5).
If the vessel is used with a water feature line
system, it must be installed in a split-return
configuration or vessel damage may occur (see
Section 3.6).
Never install the Nature
into copper plumbing as pipe damage may occur. If
brass or bronze backwash valves, or other sensitive
metallic components are installed, consult your
dealer for recommendations on your particular
system.
3.3

Anchoring the Vessel to the

Equipment Pad

In some areas building codes require that all appliances
be securely fastened to the equipment pad in order to
withstand high wind pressures created by hurricanes.
Please follow all local codes and standards.
NOTE Anchor screws and washers for securing the
vessel to the equipment pad are not included
with the vessel. Zodiac Pool Systems Canada,
Inc. ("Zodiac") recommends that a 5.7 cm X
0.6 cm (2¼" X ¼") long stainless steel concrete
screw and stainless steel flat washer are used
to mount each of the two (2) anchors in the
base to the equipment pad.
1.
Manually snap on the two (2) clip-type anchor
brackets onto the side feet of the vessel as shown
in Figure 2. Make sure these anchor brackets are
attached firmly to the feet of the vessel.
2.
Place the vessel on the pad and mark the location
of each hole of the anchor brackets on the concrete
pad.
3.
Drill a 0.5 cm (5/32") hole in the concrete at
each of the two (2) hole locations of the anchor
brackets. The correct size concrete drill bit
should be obtained when the concrete screws are
purchased.
4.
Install the screws and washers into each of the two
(2) holes to secure the vessel to the equipment pad.
Do not over-torque the screws.
Fusion feeder directly