Electrical Connection; Important - Sentiotec Wave.com4 Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Instructions for assembly and use, only for experts
Ensure electrical connection in compliance with the standards in accordance with the
connection schedule in these operating instructions!
6.0.0

ELECTRICAL CONNECTION

The safety information provided below must be precisely observed.

IMPORTANT!

The Wave.com4 control unit must be
disconnected from the mains at all poles and
safeguarded from unintentional switch-on
until all electrical work is complete.The power
unit must be connected in accordance with
the standards and by an authorised specialist
(electrician). Cables used must conform to
standards and local provisions.
IMPORTANT!
A three-pole off switch with a 3 mm contact opening must be provided for in the
installation. (Generally assured by the fuse).
WE DO IT FIRST.
IMPORTANT!
In accordance with standard EN60335
cabin light and heater must possess
separate electrical supply cables.
As the power board of the sauna control
unit is supplied via the light connection,
a light supply cable must absolutely be
executed (it must be interconnected at
the same residual current operated
circuit breaker).
43 /228

Publicité

Table des Matières
loading

Table des Matières