Electrical Wiring; Installing The Controller - Jandy Pro Series ePump + SVRS Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Jandy
Pro Series ePump
®
2.
The bonding must be accomplished by using a
solid copper conductro, No. 8 AWG or larger. In
Canada No. 6 AWG or larger must be used. Bond
the motor using the external bonding lug provided
on the motor (See figure 3).
WARNING
Always disconnect the power source before working
on a motor or its connected load.
Breaker Panel
GROUND
Circuit
Breaker
Figure 3.
Bonding the Motor
WARNING
In order to avoid the risk of property damage,
severe personal injury, and/or death, make sure
that the control switch, time clock, or control system
is installed in an accessible location, so that in the
event of an equipment failure or a loose plumbing
fitting, the equipment can be easily turned off.
CAUTION
The pump must be permanently connected to a
dedicated electrical circuit. No other equipment,
lights, appliances, or outlets may be connected to the
pump circuit, with the exception of devices that may
be required to operate simultaneously with the pump,
such as a chlorinating device or heater.
Table 2. Recommended Wire Size and Overcurrent Protection for ePumps
MINIMUM WIRE SIZE AND OVERCURRENT PROTECTION FOR ePUMP SERIES PUMPS*
Distance from Sub-panel
Model
JEP2.0SVRS
*Assumes three (3) copper conductors in a buried conduit and 3% maximum voltage loss in branch circuit. All National Electrical Code
(NEC
) and local codes must be followed. Table shows minimum wire size and branch fuse recommendations for typical installation per
®
|
+ SVRS
Installation and Operation Manual
Bonding Lug
Terminal Block
Variable-Speed
Pump (230 VAC)
Inverse - Time Circuit Breaker or Branch
Fuse AMPS
Class:CC, G, H, J, K, RK, or T
230 VAC
20A Max
ENGLISH

Electrical Wiring

1.
The pump motor must be securely and adequately
grounded using the green screw provided. Ground
before attempting to connect to an electrical power
supply. Do not ground to a gas supply line.
2.
Wire size must be adequate to minimize voltage
drop during the start-up and operation of the
pump. See Table 2 for suggested wire sizes.
3.
Insulate all connections carefully to prevent
grounding or short-circuits. Sharp edges on
terminals require extra protection. For safety,
and to prevent entry of contaminants, reinstall all
conduit and terminal box covers. Do not force
connections into the conduit box.
NOTE Since the pump is operated by either an ePump
+ SVRS controller (JEP-R), an AquaLink
controller, an AquaLink Pool Digital Assistant
(PDA), or an AquaLink Z4, the pump will not be
turned on until it is turned on with one of these
controllers.

Installing the Controller

WARNING
The Jandy Pro Series ePump + SVRS has been
designed to operate with Jandy control systems.
Operating the pump with other manufacturers'
controllers may cause software failure of the pump,
drive or other system components. This failure can
result in severe personal injury (ie. failure of the
SVRS system, electrical shock) or death.
The ePump + SVRS can be operated by one of four (4)
controllers: the ePump + SVRS controller (JEP-R), the
AquaLink RS controller (Rev O or later), the AquaLink
PDA (Rev 4.0 or later), or the AquaLink Z4.
To install the ePump + SVRS controller:
NOTE The ePump +
SVRS
1.
Remove power from the ePump + SVRS by
disconnecting the high voltage lines or by opening
any breaker to which the ePump + SVRS power is
connected.
0 - 150 Feet (0-45 meters)
208-230 VAC
#12 solid copper minimum
Page 11
®
controller part no. is
JEP-R
Voltage
RS
.
®
NEC.