Pressure Testing - Jandy Pro Series ePump + SVRS Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Page 14
ENGLISH
Wiring Diagram for 115V Aux Load,
Separate Power Sources
1
2
TP133
TP130
/100
TP127
Line
(Black)
115V
Power
Source
Neutral
(White)
(Black)
115V
Earth
Auxiliary
Load
Figure 7.
115V Aux Load, Separate Power Sources
Wiring Diagram
Wiring Diagram for 230V Aux Load,
Separate Power Source
1
2
TP133
TP130
/100
TP127
L1
(Black)
230V
Power
Source
L2
(Red)
Line
(Black)
230V
Earth
Auxiliary
Load
Figure 8.
230V Aux Load, Separate Power Sources
Wiring Diagram
Aux Load Operation Characteristics
Aux Load relay contact activation is speed-dependent,
and behaves as follows:
L2 L1
F1015
F1014
L1
(Black)
Source
L2
(Red)
Earth
Line
L2 L1
F1015
F1014
L1
(Black)
Source
L2
(Red)
Earth
Jandy
Pro Series ePump
+ SVRS
®
Contact Closure
From a stopped condition, there is a three-minute delay
before the Aux Load contact is closed when the motor
speed reaches and maintains a speed of at least 1725
RPM.
From a running condition at below 1725 RPM, there is a
230V
Power
five-second delay before the Aux Load contact is closed
when the motor speed reaches and maintains a speed of
at least 1725 RPM.
Contact Opening
If the pump speed is below 1725 RPM, the Aux
Load contact is opened. Contact openings are always
immediate.
3.5

Pressure Testing

All Jandy Pro Series ePump + SVRS pumps come with
an additional disposable o-ring for pressure testing. This
is the blue pressure test o-ring. See Figures 9 and 10.
Do not open the pump lid before pressure testing,
because the blue pressure test o-ring may fall out. If
this happens, you will need to place it back on the lid.
If you have not opened the pump lid, skip to Section
3.6, Conducting Pressure Test.
Replace Blue Pressure Test O-ring
if Necessary
If you open the pump lid before conducting the
230V
pressure test, the blue o-ring will probably fall out. If
Power
this happens, you will need to install it on the lid again
before conducting pressure testing.
There is a risk of damage to the blue o-ring during re-
installation. If you damage it when trying to re-install
it, you will need to order a new blue pressure test o-ring
before you begin conducting the pressure test.
These instructions describe the proper procedures for
replacing, using, and disposing of the blue o-ring.
These instructions must be followed exactly. Read
through the instructions completely before starting the
procedure.
Remove Pump Lid
1.
Make sure that the pump is turned off.
2.
Make sure that the switch to the circuit breaker
that powers the pump motor is turned off.
3.
Make sure all necessary isolation valves are closed
to prevent pool water from reaching the pump.
4.
Following the markings on the locking ring, turn
the ring counter-clockwise until the 'START'
markings align with the ports.
5.
Carefully remove the lid with locking ring.
|
Installation and Operation Manual
CAUTION

Publicité

Table des Matières
loading

Table des Matières