Pump Location; Pipe Sizing; Suction Pipe; Discharge Pipe - Jandy Pro Series ePump + SVRS Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Jandy
Pro Series ePump
®
Figure 2.
Typical Piping Installation

Pump Location

CAUTION
For Canadian installation, this pump carries a Type
3R enclosure rating and therefore is not intended for
installation in areas subjected to windblown dust.
1.
Zodiac
recommends installing the pump within
®
one (1) foot above water level. Refer to Figure 2
for a typical installation. The pump should not be
elevated more than three (3) feet above or below
the water level of the pool.
WARNING
This Safety Vacuum Release System (SVRS) device
is NOT compatible with the installation of check
valves. Suction check valves and hydrostatic valves
should not be used with this pump.
The SVRS feature of this pump may not operate
effectively when the pump is installed more than
3 feet above or below the water level of the pool.
Therefore, to reduce the risk of suction entrapment,
which can result in serious injury or death, DO NOT
INSTALL THE PUMP MORE THAN 3 FEET ABOVE
OR 3 FEET BELOW the water level of the pool/spa.
2.
If the pump is located below water level, isolation
valves must be installed on both the suction and
return lines to prevent back flow of pool water
during any routine or required servicing.
3.
Install the pump such that any disconnecting
means and/or junction boxes for power connection
are within site of the pump and at least five (5) feet
horizontally from the edge of the pool and/or spa.
Choose a location that will minimize turns in the
piping.
|
+ SVRS
Installation and Operation Manual
ENGLISH
AQUAPURE
NOTE In Canada the minimum distance maintained
from the edge of the pool and/or spa as noted
above must be 3m (10 feet), as required by the
Canadian Electrical Code (CEC, CSA C22.1).
4.
The pump must be placed on a solid foundation
that will not vibrate. To further reduce the
possibility of vibration noise, bolt the pump to the
foundation, or place it on a rubber mat.
NOTE Zodiac recommends bolting the pump directly to
the foundation.
5.
The pump foundation must have adequate drainage
to prevent the motor from getting wet. Protect the
pump from the rain and sun.
6.
Proper ventilation is required for the pump to
operate normally. All motors generate heat that
must be removed by providing proper ventilation.
7.
Provide access for future services by leaving a
clear area around the pump. Allow plenty of space
above the pump to remove the lid and filter basket
for cleaning.
8.
If the equipment is in a potentially dark area,
provide adequate lighting.

Pipe Sizing

Suction Pipe

The pipe size on the suction side will be 2.5 to 3 inches.

Discharge Pipe

The pipe size on the discharge side will be 2 to 3 inches.
Page 9
MANUAL BY-PASS DETAIL
MANUAL BY-PASS IS USED
WHEN FILTRATION RATE
EXCEEDS 125 GPM FOR
JANDY HEATERS. REFER
TO THE MANUFACTURERS
RECOMMENDATIONS IF USING
A DIFFERENT BRAND HEATER.