Controller
(Rear View)
4-Position
DIP Switch
Figure 4.
Wiring ePump + SVRS Controller (JEP-R)
to ePump
WARNING
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in
the ePump electrical circuit before starting the
procedure. Failure to comply may cause a shock
hazard, resulting in severe personal injury or death.
2.
Remove the cover of the ePump + SVRS junction
box and feed the RS-485 cable into the fitting.
3.
Unplug the RS-485 connector from the ePump +
SVRS.
4.
Attach the four (4) wires in the RS-485 cable to
the RS-485 connector. Match the wire colors with
the positions on the connector: 1- red, 2- black,
3- yellow, and 4- green. See Figure 4.
5.
Insert the RS-485 connector back into the ePump
+ SVRS.
6.
Slide dip switches 1 and 2 up, so they are in the
ON position, and slide switches 3 and 4 down, so
they are in the OFF position. See Figures 4.
7.
Connect the other end of the cable to the JEP-R
controller. Match the colors of the wires with the
appropriate connector positions, as described in
Step 4.
8.
Restore power to the ePump + SVRS and verify
the operation of the ePump + SVRS (JEP-R)
controller.
9.
Refer to the ePump + SVRS Controller Owner's
Manual, H0412200, to operate the pump.
Jandy
Pro Series ePump
®
5 4 3 2 1
4 3 2 1
RS485
REMOTE CONTROL
Grounding Lug
ePump + SVRS
|
+ SVRS
Installation and Operation Manual
To install an AquaLink
®
later), an AquaLink PDA (Rev 4.0 or later), or
AquaLink Z4:
1.
Remove power from the ePump + SVRS by
disconnecting the high voltage lines or by opening
any breaker to which the ePump + SVRS power is
connected.
2.
Remove the cover of the ePump + SVRS junction
box and feed the RS-485 cable into the fitting.
WARNING
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in
the ePump electrical circuit before starting the
procedure. Failure to comply may cause a shock
hazard, resulting in severe personal injury or death.
3.
Unplug the RS-485 connector from the ePump +
SVRS and attach the four (4) wires in the RS-485
cable to the RS-485 connector. Match the wire
colors with the connector positions as follows:
1-red, 2-black, 3-yellow, and 4-green.
See Figure 5.
4.
Insert the RS-485 connector back into the ePump
+ SVRS.
5.
Slide dip switches 1 and 2 down, so they are in the
OFF position. See Figure 5.
AquaLink RS
RS-485 Connectors
S1
S2
4-Position
DIP Switch
Figure 5.
Wiring AquaLink RS Controller, AquaLink
PDA or AquaLink Z4 to ePump
RS controller (Rev O or
4 3 2 1
4 3 2 1
6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
RS6 & RS8 ONLY
RS8 ONLY
RESET
POOL MODE
SPA MODE
AUTO
SERVICE
SPA DRAIN
HEATER
SOLAR
SPA FILL
TIME OUT
Connect to
AquaLink RS
RS-485 Connector
4 3 2 1
(or Multiplexer
Interface Board)
ePump + SVRS