Maximum Retention Time; Recording Scheduler - Sony SNC-EMX Serie Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 142
Network camera
Stream
Select the stream to be used for standard recordings:
Alarm recording
Select a period for the Pre-alarm time from the list box.
Select a period for the Post-alarm time from the list box.
Alarm stream
Select the stream to be used for alarm recordings:
Check the encoding interval and bit rates from profile: box and select an encoder profile to
set the associated encoding interval for alarm recording.
Alarm triggers
Select the alarm type that is to trigger a recording:
Export to account
Select an account from the drop-down box to export to an account. If an account has not yet
been defined, click Configure accounts to jump to the Accounts page where the server
information can be entered.
Click Set to apply the changes.
4.4.3

Maximum Retention Time

Recordings are overwritten when the retention time entered here has expired.
Enter the required retention time in days for each recording track.
Click Set to apply the changes.
4.4.4

Recording Scheduler

The recording scheduler allows you to link the created recording profiles to the days and
times at which the camera's images are to be recorded. Schedules can be defined for
weekdays and for holidays.
Weekdays
Assign as many time periods (in 15-minute intervals) as needed for any day of the week. Move
the mouse cursor over the table - the time is displayed.
1.
2.
3.
Sony Corporation
Continuous: the recording proceeds continuously. If the maximum recording capacity is
reached, older recordings are overwritten automatically.
Pre-alarm: recording takes place in the pre-alarm time, during the alarm and during the
post-alarm time only.
Off: no automatic recording takes place.
Stream 1
Stream 2
I-frames only
Stream 1
Stream 2
I-frames only
(Only applicable to SNC-EMX cameras) Alarm input
Analysis alarm
Virtual alarm: select one of the sensors that are to trigger a recording, via RCP+
commands or alarm scripts, for example.
Click the profile to be assigned in the Time periods box.
Click a field in the table and, while holding down the left mouse button, drag the cursor
across all of the fields to be assigned to the selected profile.
Click the No recordings profile in the Time periods box to deselect the intervals.
User manual
Configuration | en
79
2019-07 | V01 | DOC

Publicité

Table des Matières
loading

Table des Matières