Use; General Instructions On Use; Connection Of Accessories - Dräger FPS-COM 7000 Notice D'utilisation

Masquer les pouces Voir aussi pour FPS-COM 7000:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38
3

Use

3.1

General instructions on use

3.1.1
Behaviour of the communication unit
The communication unit is preconfigured with a specific number of
groups prior to delivery according to customer specifications.
Additional groups can be set using the configuration software.
When the communication unit is switched on, it starts in the factory
setting with "Group one".
Dräger recommends establishing rules for use and switching between
groups and ensuring training is carried out. If several fire stations use
the communication units in the same operating area, the groups
should be split among the different fire stations and common groups
should be defined.
If there are several crews in one operation, the first crew which is
deployed should select the highest group ID. Subsequent crews and
crews on standby should employ the following group IDs in
descending order to avoid disturbing those crews which have already
been deployed.
If group members leave the reception range for a group, the
communication units automatically create a new group with the same
group ID. This ensures communication is maintained between the
members leaving the group. If groups with the same group ID meet
each other, they are automatically merged to form one group (see
page 4, Fig. B and C).
3.1.2
Display of operating status conditions
The communication unit provides information on specific status
conditions using the LED and signal tones (see first fold-out page).
When the LED flashes this means:
Dräger FPS-COM 7000
1
Ready for operation
2
Start
data transfer to PC, where applicable
3
Installation of an update to internal processors
or
shut-down
4
Bluetooth pairing
5
Bluetooth connection between communication unit and radio is
restored
6
Warning: Battery charge has decreased to only 25 %
7
Warning: Battery charge has decreased to only 10 %
8
Warning: Fault
9
Warning: Battery voltage too low, the communication unit is not
activated
3.1.3

Connection of accessories

The communication unit may only be used in potentially explosive
atmospheres with accessories that are intrinsically safe. If accessories
that have not been approved by Dräger are used, compliance must be
ensured with the parameters specified in the supplement 9031244.
NOTICE
i
i
The voice quality of the communication unit can be influenced
by the connected radio and its settings.
3.1.4
Switching on the communication unit
Press the ON/OFF button for approx. 1 second.
The LED lights up in green and an acoustic signal indicates that
the communication unit is operational.
3.1.5
Switching off the communication unit
Press the ON/OFF button for at least 3 seconds.
The LED flashes green and an acoustic signal indicates that the
communication unit is switched off.
Use
27

Publicité

Table des Matières
loading

Table des Matières