5.5

Digital communication

5.5.1

HAR protocol

The device is registered with the HART Communication
Foundation.
Fig. 19: Communication via HART protocol
HART protocol
Configuration
— Directly on the device
— Via software DSV401 + HART-DTM
Transmission
FSK modulation on voltage output 4 ... 20 mA
according to Bell 202 standard
Baud rate
1200 baud
Display
Logic 1: 1200 Hz
Logic 0: 2200 Hz
Maximum signal
1.2 mAss
amplitude
Load at current output
250 ... 560 Ω
(in hazardous area: maximum 300 Ω)
Cable
Design
Two-wire cable AWG 24, twisted
Maximum length
1500 m (4921 ft)
See the interface description for detailed information.
22 - EN CI/FCB300/FCH300-X1 Rev. F | CoriolisMaster FCB330, FCB350, FCH330, FCH350

System integration:

Communication (configuration, parameterization) can be
performed with the DTM (Device Type Manager) available for
the device and the corresponding framework applications as
per FDT 0.98 or 1.2 (DSV401 R2).
Other tool/system integrations (e.g., Emerson AMS/Siemens
PCS7) are available on request.
The necessary DTMs can also be downloaded from
www.abb.com/flow.