Maintenance And Cleaning; Button Functions; Technical Data - VOLTCRAFT IR-SCAN-350RH/2 SE Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Inserting / replacing the battery
• Open the battery compartment cover (10).
• Connect a 9 V monobloc battery to the matching terminal inside the battery compartment.
• Close the battery compartment.
Replace the battery when the battery icon appears on the top right side of the
display.

Button Functions

• Press the release button (9)
- once, to turn the product on.
- once during measurement, to freeze the readings last shown on the display. The indication
"HOLD" appears on the display (5). To continue with the measurement, press the release
button again.
- for approx. 2 seconds to turn the product off.
• Press the laser button (3)
- once to activate the dual-target laser (2),
- twice to deactivate the target laser (2).
• Press the button MODE (7) to toggle between the various display units in the top half of the
display:
- Dew point temperature ("DP" indicator)
- Ambient temperature ("AT" indicator)
- Ambient humidity ("%RH" indicator)
• Press the button ºC/ºF (6)
- to toggle the temperature display unit between Celsius and Fahrenheit.
- for approx. 2 seconds to turn the beep on/off. The display (5) will show the symbol (beep
on) or (beep off).
Notes on the measuring procedure
a) Operating principle
• IR thermometers measure the surface temperature of an object. The sensor on the device
records the heat radiation emitted, reflected and transmitted from the object, and converts
this information into a temperature value.
• The emission level is a value used to describe the energy radiation characteristics of a
material. The higher the value, the more capable the material is of emitting radiation. Many
organic materials and surfaces have an emission level of approx. 0.95. Metallic surfaces
or shiny materials have a lower emission level and therefore return inaccurate measured
values.
• The ambient sensor measures the ambient temperature and humidity. From this, the
dew point is calculated. The infrared sensor measures the surface temperature and then
compares it with the calculated dew point temperature. The closer the value of the surface
temperature is to the dew point temperature value, the higher the risk of mould formation on
the measured surface.
b) Measurement distance / measurement surface area ratio (D/S)
• To achieve accurate measurements, the target must be larger than the thermometer's
measuring area. The measured temperature is the average temperature of the area
measured.
• The smaller the target, the smaller the measurement distance between thermometer and
target object has to be.
• The distance to target / size of IR focal spot ratio is 20:1. With a distance of 20 cm to the
target, the size of the IR focal spot is thus 1 cm.
Taking Measurements
• Turn the product on and activate the target laser (2), if required.
The measuring surface is in the middle between the two laser points. The closer
you are to the surface, the more accurately you can aim on the desired measuring
surface.
• The maximum distance from the measuring surface should not be greater than 2 m.
• Now start scanning the surface slowly. Point the IR sensor (1) as vertically to the measuring
surface as possible.
• In the lower display (5) area, the surface temperature of the measuring surface will be shown.
In the upper display area, the ambient sensor (8) reading will be shown.
• The right-hand side of the display shows the bargraph display. The higher the bar indicator is,
the greater the risk of mould formation.
- The 3-colour warning LED (4) is located above the display. When the LED lights up
- green, there is no risk of mould formation.
- yellow, there is an increased risk of mould formation.
- red, there is an acute risk of mould formation, or the measuring surface has already been
affected by mould.
• If the yellow LED lights up, in addition a beep tone will sound. If the red LED lights up, in
addition a continuous beep tone will sound.
The device will turn off automatically approx. 15 minutes after having been turned on
with the release button (9).
• If the HOLD function (press release button during measurement) is activated, the device
turns off automatically after approx. 20 seconds. Legal notice

Maintenance and cleaning

• The device requires no servicing on your part apart from occasional cleaning. Only use a soft,
anti-static and lint-free cloth for cleaning.
• Do not use abrasive or chemical cleaners.
Disposal
a) Product
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product in accordance
with applicable regulatory guidelines.
Remove any inserted rechargeable batteries and dispose of them separately from
the product.
b) Rechargeable Batteries
You as the end user are required by law (Battery Ordinance) to return all used
rechargeable batteries. Disposing of them in the household waste is prohibited.
Contaminated rechargeable batteries are labeled with this symbol to indicate that
disposal in the domestic waste is forbidden. The designations for the heavy metals
involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on rechargeable
batteries, e.g. below the trash icon on the left).
Used rechargeable batteries can be returned to collection points in your municipality, our stores
or wherever rechargeable batteries are sold.
You thus fulfill your statutory obligations and contribute to the protection of the environment.

Technical data

Operating voltage
Optics
Emission level
IR wavelength
Laser class
Laser wavelength
Max. laser output power
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Dimensions (W x H x D)
Weight
Measuring range
-50 ºC to +20 ºC
-58 ºF to +68 ºF
Temperature
+20 ºC to +380 ºC
+68 ºF to +716 ºF
0% - 20% rF
Humidity
20% - 80% rF
80% - 100% rF
-30 ºC to +100 ºC
Dew point temperature
-22 ºF to +212 ºF
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights
including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represents the technical status at the time of printing.
Copyright 2019 by Conrad Electronic SE.
9 V block battery
20:1
0.95 (fixed)
8 - 14 μm
2
630 - 670 nm
<1 mW
0 ºC to +50 ºC / +32 ºF to +122 ºF
<80% RH
-20 ºC to +60 ºC / -4 ºF to +140 ºF
10% to 90% RH
82 x 168 x 58 mm
163 g
Accuracy
Resolution
±5 ºC
±9 ºF
±1,5 % +2 ºC
±1,5 % +5 ºF
0,1
4,5%
3,5%
4,5%
---
*2109292_v1_0619_02_dh_m_en