Please Read Immediately; Important Notes; Intended Use; Legal Regulations And Guidelines - Dimplex LAW 9IMR Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LAW 9IMR - LAW 14ITR
1
Please read
immediately

1.1 Important notes

ATTENTION!
Never use cleaning agents containing sand, soda, acid or chloride, as
these can damage the surfaces.
ATTENTION!
Before opening the device, ensure that all electric circuits are
disconnected from the power supply.
ATTENTION!
The indoor unit is to be fixed to the transport pallet with screws.
ATTENTION!
In an unfilled state (buffer tank and domestic hot water cylinder without
water), the device has a tendency to tilt in the direction of the hydraulic
assembly. Do not lean on the rear of the unit!
ATTENTION!
Operating the heat pump at low system temperatures may cause the heat
pump to break down completely. After a prolonged power failure, the
commissioning procedure detailed above must be followed.
ATTENTION!
Work on the system must only be performed by authorised and qualified
after-sales service technicians!
ATTENTION!
Incorrect filling with refrigerant could lead to faults during operation.
ATTENTION!
Never open the valves of the outdoor component. Carry out the work from
Chapt. 8.2 on page 11 and Chapt. 8.3 on page 12 first of all.
The operational reliability of the safety valve must be checked at
regular intervals. We recommend having an annual service in-
spection carried out by a qualified specialist company.
The outflow from the safety valve should visibly flow into a waste
water drain.
The installer of the heating system is responsible for checking
whether an additional expansion vessel is required.
Operating the system in a sensible way can provide significant
energy savings. The heating water temperature should be as low
as required during heat pump operation. The planner of the heat-
ing system is responsible for determining the system tempera-
ture.
When installing an underfloor heating system, a sensible value
for the maximum flow and return temperature should be set on
the heat pump manager. The position of the temperature sensor
is important in this regard.
EN-2

1.2 Intended use

This device is only intended for use as specified by the manufac-
turer. Any other use beyond that intended by the manufacturer is
prohibited. This requires the user to abide by the relevant project
planning documents. Please refrain from tampering with or alter-
ing the device.
1.3 Legal regulations and
guidelines
This heat pump is designed for use in a domestic environment
according to Article 1, Paragraph 2 k) of EC directive 2006/42/EC
(machinery directive) and is thus subject to the requirements of
EC directive 2006/95/EC (low-voltage directive). It is thus also in-
tended for use by non-professionals for heating shops, offices
and other similar working environments, agricultural establish-
ments and hotels, guesthouses and other residential buildings.
The construction and design of the LAW device complies with all
relevant EU directives, DIN and VDE regulations (see CE de-
claration of conformity).
When connecting the LAW device to the power supply, the rele-
vant VDE, EN and IEC standards are to be fulfilled. Any further
connection requirements stipulated by the mains supply network
operator must also be observed.
When connecting the heating system, all applicable regulations
must also be adhered to.
Persons, especially children, who are not capable of operating
the device safely due to their physical, sensory or mental abilities
or due to their inexperience or lack of knowledge, must not oper-
ate this device without supervision or instruction by the person in
charge.
Children must be supervised to ensure that they do not play with
the device.
452162.66.04 · FD 9309
www.dimplex.de