Device Information; Operating Limits - Dimplex LAW 9IMR Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LAW 9IMR - LAW 14ITR

13 Device information

1
Type and order code
2
Design
Heat source
2.1
Model
2.2
Controller
2.3
Thermal energy metering
2.4
Installation location
2.5
Performance level
3

Operating limits

3.1
Heating water flow / return
3.2
Cooling water flow
3.3
Air (heating)
3.4
Air (cooling)
4
Flow / sound
4.1
Heating water flow / internal pressure differential
in accordance with EN 14511
free compression
Minimum heating water flow
free compression
4.2
Noise-power level in accordance
1
with EN 12102 outdoors
4.3
Sound pressure level in 10 m distance outdoors
4.4
Noise-power level in accordance
with EN 12102 indoors
4.5
Sound pressure level in 1 m distance indoors
4.6
Air flow
5
Dimensions, weight and filling quantities
3
5.1
Device dimensions
5.2
Weight of the transportable unit(s)
incl. packaging internal / external
5.3
Device connections for heating
5.4
Refrigerant; total filling weight
5.5
Lubricant; total filling quantity
5.6
Volume of heating water in the outdoor component
5.7
Buffer tank
Nominal volume
Permissible operating temperature
Max. operating overpressure
Electrical pipe heater
Immersion heater (optional)
5.8
Domestic hot water cylinder
Usable capacity
Heat exchanger area
Permissible operating temperature
Max. operating pressure
Immersion heater
5.9
Start-to-leak pressure, safety valve
EN-18
°C
°C
°C
°C
m³/h / Pa
Pa
m³/h
Pa
dB(A)
2 1
dB(A)
dB(A)
dB(A)
m³/h / Pa
internal
H x W x D mm
external
H x W x D mm
kg
inches
type/kg
type/litres
Litres
in litres
°C
bar
kW
kW
in litres
°C
bar
kW
bar
452162.66.04 · FD 9309
LAW 9IMR
Air
Split reversible
WPM Econ5Plus integrated
Yes
Indoors / outdoors
Variable
up to 55 / from 18
7 to 25
-20 to +30
+10 to +43
1,6 / 20000
38800
0,75 / 8500
68500
63
32
42
35
3600
1920 x 740 x 950
834 x 950 x 330
215 / 69
G 1 1/4"
R410A / 1.9
Polyvinyl ether (PVE) / 0.9
0
100
85
3,0
4
2, 4 or 6
up to 6
277
3,15
95
10,0
1,5
2,5
LAW 14ITR
Air
Split reversible
WPM Econ5Plus integrated
Yes
Indoors / outdoors
Variable
up to 55 / from 18
7 to 25
-20 to +30
+10 to +43
2,4 / 30400
29600
0,9 / 10000
77300
67
36
42
35
3600
1920 x 740 x 950
1380 x 950 x 330
222 / 116
G 1 1/4"
R410A / 2.98
Polyvinyl ether (PVE) / 1.3
0
100
85
3,0
4
2, 4 or 6
up to 6
277
3,15
95
10,0
1,5
2,5
www.dimplex.de

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Law 14itr

Table des Matières