Maintenance Work - Lombardini - Ammann AVP 1240-2 Traduction Du Mode D'emploi Original

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. Maintenance
5.8 Maintenance work — Lombardini
Only the maintenance work which has to be performed daily
is included in this operating manual. Please refer to the en-
gine operating manual and to the maintenance instructions
and intervals listed therein.
5.8.1 Filling up with fuel
Only top-up by stationary engine.
No open fire.
Danger
Do not smoke.
Do not fill-up in closed rooms.
Do not inhale petrol fumes.
Collect spilt fuel in a suitable container and pre-
vent spillage entering the soil.
B1799212.cdr
Clean around the fuel filler socket.
Open the fuel filler socket and
Visually check the fuel level. An unusable amount of fuel re-
mains in the tank due to the design.
Top-up if necessary; all diesel oils sold as fuel and complying
with the following minimum specification can be used: EN 590;
DIN 51601 - DK; BS 2869 A1 / A2; ASTM D 975 - 1D / 2D.
Close the tank tightly.
5.8.2 Checking the engine oil level
Environment
Position the vibration plate so that the engine is in vertically
upright position.
Clean around the dipstick area.
l
max. 3
/
0,79 US gal
1
1
B1799214.cdr
Pull out dipstick (1) and wipe clean.
Push dipstick back in with twisting movement by hand, then
pull out again with similar twisting movement.
Read off the oil level on the dipstick, and if necessary top to
the «max» mark.
SAE 10W/40
B1799215.cdr
-
Open the oil filler cap (2).
-
Fill up with oil.
Close the oil filler cap (2).
59
Immediately replace damaged seals.
Collect old oil and dispose of it in an environment
friendly manner.
Do not permit oil to run onto the floor into the
drains.
max
min
OIL
1
2

Publicité

Table des Matières
loading