THERMOTECHNICAL CHARACTERISTICS
Nominal power
Efficiency nominal power
Emissions CO (13% O2) nominal power
Smoke mass nominal power
Reduced power
Efficiency reduced power
Emissions CO (13% O2) reduced power
Smoke mass reduced power
Nominal power maximum smoke temperature
Reduced power smoke temperature (average)
Minimum draught
Autonomy (min/max)
Fuel consumption (min/max)
Hopper capacity
*
Heatable volume
Weight FORMA including packaging
Weight TWIN including packaging
Smoke outlet pipe diameter (male)
Air intake pipe diameter (male)
*
The heatable room dimensions are calculated on the basis of pellets with an lhv of at least 4300 kcal/kg and home insulation in
compliance with Italian law 10/91, and subsequent changes together with an expected heat output of 33 Kcal/m³ per hour.
*
It is also important to consider the position of the stove in the room to be heated.
The data shown above is purely indicative. EDILKAMIN s.p.a. reserves the right to make changes to these pro-
ducts to improve their performance with no prior warning.

ELECTRICAL CHARACTERISTICS

Power supply
On/off switch
Average power consumption
Power consumption during ignition
Remote control frequency
Protection on mains power supply* (see page 24)
Protection on electronic circuit board

SAFETY DEVICES

THERMOCOUPLE:
placed at the smoke outlet to detect the temperature. Turns the stove on and off and controls its operation based on defined
parameters.
HEARTH SAFETY MICROSWITCH:
a microswitch located on the hearth door ensures that the product operates only when the door is correctly closed.
SAFETY THERMOSTAT:
trips when the temperature inside the stove is too high.
It stops pellet loading, causing the stove to go out.
INTAKE TEMPERATURE SENSOR
located on the combustion air intake duct, this sensor verifies that the temperature stays within the pre-established limits for
ensuring correct operation.
FEATURES
25
6
95,4
0,013
4,4
2
96,2
0,026
2,4
77
54
12
9/20
0,6 / 1,3
15
188
152
222
80
80
230Vac +/- 10% 50 Hz
Yes
100
W
400
W
Infrared
2AT, 250 Vac, 5x20 Fuse
2AT, 250 Vac, 5x20 Fuse
kW
%
%
g/s
kW
%
%
g/s
°C
°C
Pa
hours
kg/h
kg
m
3
kg
kg
mm
mm