THERMO TECHNICAL CHARACTERISTICS
Thermal power output
Thermal power transferred to the water without fan
Thermal power transferred to the environment
Yield / Effi ciency
Emissions CO 13% O
2
Fume temperature
Fuel consumption
Draught
Hopper capacity
Water content
Maximum operating pressure of the water
Maximum operating temperature of the water
Autonomy
Heatable volume *
Smoke outlet pipe diameter (male)
Air intake pipe diameter (male)
Weight including packaging (ceramic/steel)
TECHNICAL DATA FOR SIZING THE FLUE which must, in any case, comply with the guidelines of
this sheet and the installation rules for each product
Thermal power output
Temperature of fumes on exit from the discharge pipe
Minimum draught
Fume fl ow capacity
* The heatable room dimensions are calculated on the basis of home insulation in compliance with Italian law 10/91, and subse-
quent changes together with an expected heat output of 33 Kcal/m³ per hour.

ELECTRICAL CHARACTERISTICS

Power supply
Average power consumption
Power consumption during ignition
Protection on electronic circuit board
N.B.
1) keep in mind that external devices can cause interference to the operation of the circuit board.
2) warning: activity on live components, maintenance and/or checks must be carried out by quali ed personnel.
(before carrying out any maintenance, disconnect the appliance from the mains electricity)
3) In case of problems with the electrical grid, consult an electrician to evaluate the installation of a sine-wave UPS of at
least 800 Va. Power variations greater than 10% can cause problems for the product.
The above data are indicative and are those resulting during certi cation on the part of the noti ed body.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.
GENERAL INFORMATION
according to EN 14785 (for other values, see DoP on page 40)
Nominal power
13
10
3
91,6
0,010
129
3
12 - 5
30
12
1,5
90
9
340
80
40
250 / 230
Nominal power
13
155
0 - 5
10,6
230Vac +/- 10% 50 Hz
120 W
400 W
T2A, 250 Vac, 5x20 Fuse
- 37
-
Reduced power
3,9
kW
3
kW
0,9
kW
97,6
%
0,025
%
56
°C
0,8
kg/h
10 - 3
Pa
kg
Litres
bar
°C
34
hours
3
m
mm
mm
kg
Reduced power
3,9
kW
67
°C
Pa
3,6
g/s

Hide quick links: