5. If the device topples over, switch it off immediately
with the ON/OFF button (14) and disconnect the
device from the mains with the mains connection
cable. There is a risk of electric shock! First return
the device to the upright, standing position. For your
own safety, wait about five minutes before re-estab-
lishing the electrical connection.
6. Switching off: Press the ON/OFF button (14) again.
The operation LED (15) goes out and the heating
process is ended with the displayed temperature
7. Disconnect the device from the mains. The mains
connection is only required to heat up the water.
Charging the battery (Fig. 5/ 8)
1. The weed killer has an integrated Li-Ion battery for
operation of the water pump.
2. The battery is charged automatically when the week
killer is connected to the mains and the ON/OFF
button is pressed.
3. You can see the charge status of the battery on the
charge status display (18).
Operation (Fig. 1; 5-8)
Important note: Only regular use of the device will
ensure effective weed control. The weeds will only
die off after a certain amount of time has passed
following treatment.
1. Switch on the weed killer with the ON/OFF button
(14). Make sure that the device is disconnected
from the mains.
2. If no settings, etc. are made on the device within
one (1) minute, it automatically switches off.
3. Press the 'Pump' button (19) once. The 'Pump'
LED (20) begins to illuminate and a beep is is-
sued. The charge status display also begins to il-
luminate.
4. Remove the lance (9) from the lance holder (13).
5. Direct the nozzle (10) towards weeds. Attention!
The jet must not be directed towards any per-
sons, animals, active electrical equipment or
the device itself.
6. The width of the water jet can be adjusted by turn-
ing the nozzle (10).
7. Wait a few seconds until the pump has built up
enough pressure.
8. Actuate the activation lever (7). The activation le-
ver (7) can be locked with the locking button (8).
9. Spray weeds for a few seconds with hot water.
The hotter the water, the more quickly the plant
protein is destroyed. Ensure that hot water also
penetrates to the root of the weed. This is the only
way to permanently remove the weed. Make sure
that you bring the nozzle (10) as close as pos-
sible to the weed.
10. The device can be used in the same manner to
water plants with cold water, or for the applica-
tion of fungicides, pesticides, fertilisers or clean-
ing agents that are water-soluble, as well as for
disinfecting and cleaning of dirt and stains with hot
water.
20 І GB
 www.scheppach.com  service@scheppach.com  +(49)-08223-4002-99  +(49)-08223-4002-58
11. This device was developed for use with a neutral
cleanser based on biodegradable anionic surface-
active agents. Use of other cleaning agents or
chemical substances can impair the safety of the
device and cause damage. Such damage to the
device is not covered under warranty. Only use
biodegradable fungicides, pesticides or herbicides
that do not corrode the stainless steel tank and
other device parts. Only use water-soluble addi-
tives and ensure that they have completely dis-
solved in the water. Otherwise, residue can clog
the pump, hose (26), lance (9) and nozzle (10).
12. Press the 'Pump' button (19) again to end opera-
tion. The 'Pump' LED (20) goes out.
13. Press actuate the activation lever (7) again in or-
der to de-pressurise the hose (25) and lance (9)
and remove the water.
Transport
1. Before any transport, turn the machine off and dis-
connect it from the power supply.
2. Please use only the handle (6) to transport the ma-
chine.
3. Protect the machine from blows, impact and strong
vibrations, e.g. during transport in vehicles.
4. Secure the machine against tilting and sliding.
5. Never use safety guards for handling or transport.
Cleaning
c Remove the mains plug before any work on
the machine. This also includes filling with water
or the attempt to remove leaks. Risk of electric
shock!
Do not hose the machine down with water and do
not clean it under running water. There is a risk of
electric shock and the machine can be damaged.
Always keep the machine clean. Do not use deter-
gents or solvents.
• Keep the ventilation slots clean and free.
• Clean the machine with a soft brush or a damp cloth.
• If the nozzle (10) is dirty or blocked, you can re-
move the foreign body from the nozzle with a nozzle
cleaning needle.