Problem
An alarm for a too high
voltage.

6 Technical data

Power supply
Power consumption
without dial illumination
dial illumination
Shunt supplied
Protection
Ambient temperature
Display
Voltage
Current
Battery capacity
Discharge time
Battery Monitor
Possible cause
Voltage is too high.
The value entered for the
alarm is too low.
:
12 .. 24 V direct current
,
:
45 mA at 12 V, 30 mA at 24 V
:
55 mA at 12 V, 35 mA at 24 V
:
200 A / 100 mV
:
IP66 (only the front of the instrument, after instal-
lation)
:
0 .. 50°C
Range
:
9 .. 32.6 V
:
-200 .. +200 A
:
0 .. 100%
:
0 .. 999 hour
Solution
Check the alternator volt-
age regulator and/or the
battery charger.
Enter a higher value, see
3.6.
Resolution
0.1 V
0.5 A,
for a 200 A / 100 V shunt
0.1% (digital)
0.1 hour