Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
• Press the right push button to en-
ter
  Battery 
mode.
• Adjust the value of the battery ca-
pacity and press both push buttons
simultaneously for at least 3 seconds
to confirm.
If the battery is in poor condition (old,
often been discharged and re-charged,
etc.) then enter a lower value then the
battery capacity as stated on the bat-
tery. A battery of 3 years old can have a
capacity of only 80 %.

3.3 Shunt

De supplied shunt is specified for 200 A
/ 100 mV.
If a shunt with a different specification is
installed the value for the shunt must be
adapted.
Battery Monitor
t
ip
• Go to
  Battery  Monitor  Setup 
'2 Operation'.
• Press both push buttons simultane-
ously for at least 3 seconds to se-
lect
  Battery  Monitor  Setup 
'4 Entering current capacity shunt'.
• Press the left push button once to se-
lect
  Shunt 
.
• Press the right push button to en-
ter
  Shunt 
mode.
• Adjust the value of the shunt and
press both push buttons simultane-
ously for at least 3 seconds to confirm.
Specification
shunt
200 A / 100 mV
100 A / 100 mV
80 A / 60 mV
100 A / 60 mV
200 A / 60 mV
ENGLISH
see
, see
Value to be set
200 A
100 A
133 A
167 A
333 A
15
090433.01

Publicité

Table des Matières
loading

Table des Matières