1 Introduction

The Vetus battery monitor can be used
to measure the charge condition of the
battery and also, while discharging, the
time remaining before the battery will
be completely discharged.
The following functions can be read:
- the charge condition of the battery
- the charge or discharge current
- the voltage
- the time limit before the battery is
completely discharged.
A number of alarms can also be set.
The battery monitor can be connected
to both a 12 Volt and a 24 Volt system,
with negative earthed or earth free (2
pole).
1.1 Explanation used text for-
matting
'Text' : Reference to information on
separate sheet.
Text
: Text in the display.
12
090433.01

2 Installation

2.1 Meter

• Click the ring onto the meter. Make a
hole in the panel and fit the meter.
2.2 Shunt, converter and main
battery cables
• Install the shunt near the battery or
batteries
• Place the converter as close as pos-
sible to the shunt and keep the con-
necting wires between shunt and
converter as short as possible.
• Fit a fuse and a main switch in the
positive "+" cable.
• Use cable terminals to connect the
cables to the shunt, the fuse and the
switch. Preferably fit cable terminals
by crimping.
• Tighten bolts and nuts securely to en-
sure a good connection.