elco AEROTOP SPLIT M-RX Guide D'installation page 83

Table des Matières
Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 150
Setting
periods confi gured with the domestic
water auxiliary schedule program-
ming function.
17.5.3 Max HP charging time
Defi ne the charging time of the DHW
tank done only with the heat pump.
When this time elapses, the integration
resistors are switched on.
Press the OK button to confi rm. Turn the
knob and select:
17.5.4 Thermal Cleanse
Function Function
Activating this function, the sanitary
water tank is heatted up at 60°C for 1h
every 30 days .
Press the OK button to confi rm. Turn the
knob and select:
- ON (enable function)
- OFF
17.5.5
Thermal
Cleanse
start time
Defi ne the start time of the thermal cle-
anse function
17.5.6 Thermal Cleanse Function fre-
quency
Set the period after wich a new Thermal
Cleanse is performd
Turn the knob and select:
17.6
MANUAL MODE - 1
Manual activation of the system com-
ponents (circulators, diverter valve, resi-
stors, etc)
17.7
MANUAL MODE - 2
17.7.1 Force Hp Heat
Activate the heat pump in heating
mode
17.7.2 Force Hp Cool
Activate the heat pump in cooling
mode
17.7.3 Rating Heating Mode
17.7.4 Rating Cooling Mode
17.7.5 Fixed compressor frequency
Defi ne the compressor frequency du-
ring the working mode of the heat
pump selected by the parameters
17.7.1 or 17.7.2.
In manual mode the heat pump keeps
the protection logics active, therefore
the compressor frequency might be dif-
ferent from the set one.
Turn the knob and select:
17.8
TEST & UTILITIES
Press the OK button to confi rm.
Turn the knob and select:
17.8.0 Air-purge function
Active the air purge cycle of the system;
the air purge duration is 18 minutes.
Press the OK button to confi rm. Turn the
knob and select:
17.8.1 Floor drying cycle
defi ne the fl oor drying cycle mode:
- 0. OFF
- 1. Functional Heating
(fl oor drying done at fi xed temperatu-
re of 55°C for 6 days)
60
55
Function
50
45
40
35
30
25
20
15
0
1
2
- 2. Curing Heating
(fl oor drying done with variable tem-
perature from 25°C to 55°C according
to the profi le reported in the picture
below for 18 days)
60
55
50
45
40
35
30
25
20
15
0
2
4
6
3
4
5
6
7
8
9
10
8
10
12
14
16
18
20
- 3. Functional Heating +
Curing Heating
(fl oor drying done at fi xed temperatu-
re of 55°C for 6days and then with va-
riable temperature from 25°C to 55°C
for the following 18 days)
60
55
50
45
40
35
30
25
20
15
0
5
10
15
- 4. Curing Heating +
Functional Heating
(fl oor drying done with variable tem-
perature from 25°C to 55°C for the fi rst
18 days and then at fi xed temperature
of 55°C for the following 6 days)
60
55
50
45
40
35
30
25
20
15
0
5
10
15
- 5. Manual
(fl oor drying done at the setpoint tem-
perature set by the parameter 17.3.9)
20
25
30
20
25
30
83 / GB
Table des Matières
loading