ENGLISH
1. Loosen the screws (12) and slide one chip
protection plate (13) upwards.
2. Turn the indexable insert holder (18) manually if
necessary.
3. Unscrew the fastening screw (20) and remove
the indexable insert (19).
4. Clean indexable insert (19) and clamping
surfaces on the indexable insert holder (18).
5. Turn the indexable insert or, if all blades are
blunt, replace the indexable inserts.
6. Fix again the indexable insert (19) with a
fastening screw (20). Torque: 3.5 Nm.
7. Slide the chip protection plate (13) all the way
down. Tighten the screws (12).
Note: Causes for indexable inserts with broken
corners or, in extreme cases, for broken indexable
inserts, can include:
- Impacts on the indexable insert due to incorrect
use: See chapter 8.2.
- Workpiece vibrations: Fix workpiece without
vibrations using clamping devices.
- Indexable insert not correctly fastened: Always
clean clamping surfaces and note torque.
- Indexable insert not correctly fastened: Strongly
worn Indexable inserts do not have sufficient
contact surfaces and therefore may not be
fastened sufficiently. Replace the strongly worn
indexable inserts.
10. Cleaning
Pull the mains plug out of the socket.
Chips and particles can deposit at the milling head
(18). This can lead to blockage of the milling head.
Regularly clean the milling head and its
surroundings and remove chips and particles.
It is possible that particles deposit inside the power
tool during operation. This impairs the cooling of the
power tool. Conductive build-up can impair the
protective insulation of the power tool and cause
electrical hazards.
The power tool should be cleaned regularly, often
and thoroughly through all front and rear air vents
using a vacuum cleaner. Prior to this operation,
separate the power tool from the power source and
wear protective goggles and a dust mask.
11. Troubleshooting
KFM 15-10 F, KFMPB 15-10 F:
The electronic signal indicator (10) lights
up and the load speed decreases. There is
too much load on the machine! Run the
machine in idling until the electronic signal indicator
switches off.
18
-The machine does not start. The
electronic signal indicator (10) flashes
(depending on the model). The restart
protection is active. If the mains plug is inserted with
the machine switched on or if the power supply is
restored following an interruption, the machine
does not start up. Switch the machine off and on
again.
KFM 16-15 F:
- Restart protection: if the mains plug is inserted
with the machine switched on or if the power
supply is restored following an interruption, the
machine does not start up. Switch the machine off
and on again.
- Overload protection: there is a reduction in
load speed. The coil temperature is too high!
Allow the machine to run at idle speed until it has
cooled down.
- Switching on the machine briefly reduces the
voltage. Unfavourable mains power conditions
may have a detrimental effect on other machines.
Power impedances less than 0.4 ohm should not
cause malfunctions.

12. Accessories

Use only genuine Metabo accessories.
Use only accessories that fulfil the requirements
and specifications listed in these operating
instructions.
Fit accessories securely. If the machine is operated
in a holder: secure the machine well. Loss of control
can cause personal injury.
A 10 HM universal inserts......................6.23564
B Fastening screw for inserts ................6.23566
C Cooling lubrication stick .....................6.23443
For a complete range of accessories, see
www.metabo.com or the catalogue.
13. Repairs
Repairs to power tools must only be carried
out by qualified electricians!
Contact your local Metabo representative if you
have Metabo power tools requiring repairs. See
www.metabo.com for addresses.
You can download a list of spare parts from
www.metabo.com.

14. Environmental Protection

Observe national regulations on environmentally
compatible disposal and on the recycling of disused
tools, packaging and accessories.
Only for EU countries: never dispose of
power tools in your household waste! Used
power tools must be collected separately and
handed in for environmentally compatible recycling
in accordance with European Directive 2002/96/EC
on waste electrical and electronic equipment and its
implementation in national legal systems.