ENGLISH
removal process is started automatically. After the
one-time rS-setting process, the last set value for
the setting force appears again on the display (8).
Re-setting one or several blind rivet nuts:
If one or several nuts have been set with too
low a force value, these nuts can be re-set in rr-
mode (reWork).
- To this end, it is first necessary to determine the
correct numerical value for the setting force and to
correct it on the display (see point 6.3).
- Subsequently, press the S-button (7) and skip the
memory locations (P1-9) until rr appears in display
7.
- Afterwards, all incorrectly set nuts can be re-set
with the corrected value for the setting force, by
threading on the corresponding nuts again and
starting a new setting process by pressing the
switch (9) until the automatic removal process is
started.
- When all blind rivets are re-set, you can switch to
normal mode by pressing the S-button again.
7.4
Light
The rivet nut gun has 3 LEDs to illuminate the
workplace, which can be switched on by turning the
black ring behind the LEDs. There are 3 positions,
indicated by the arrow injected into the housing and
the "light sign" icon (see P.2 fig. 3):
Continuous light/torch function I:
The illumination is switched on after a riveting
process and stays on for about 10 minutes. Then all
LEDs go out automatically.
Zero position 0:
Light switched off.
Working light A (fig. 3):
Illumination is switched on at the start of the riveting
process. The LEDs light up for about 10 seconds
and then go out automatically.

8. Maintenance and Cleaning

Remove the battery pack before
completing any maintenance or cleaning
on the device!
The rivet nut gun maintenance is limited to the
replacement of work threaded mandrels and nose
pieces as required (for replacement of the threaded
mandrels, see item 6.1).
Regular maintenance will extend the service life of
your machine and should be carried out at least
every 2 years by an authorised workshop or Metabo
service. More frequent maintenance is
recommended for intensive use.
f

9. Accessories

Use only original Metabo or CAS (Cordless Alliance
System) battery packs and accessories.
12
Use only accessories that fulfil the requirements
and specifications listed in these operating
instructions. Fit accessories securely.
Charger: ASC 30-36, etc
Battery packs with different capacities. Buy
battery packs only with voltage suitable for your
power tool.
Order no.: 6.25367 .... 4,0 Ah (LiHD)
Order no.: 6.25596 .... 2.0 Ah (Li-Ion)
etc.
10. Repairs
Repairs to electrical tools must ONLY be carried out
by qualified electricians!
Contact your local Metabo representative if you
have Metabo power tools requiring repairs. For
addresses see www.metabo.com.
You can download a list of spare parts from
www.metabo.com.

11. Environmental Protection

Observe national regulations on environmentally
compatible disposal and on the recycling of disused
machines, packaging and accessories.
Only for EU countries: never dispose of
power tools in your household waste!
According to European Directive 2012/96/EU
on Waste from Electric and Electronic Equipment
and implementation in national law, used power
tools must be collected separately and recycled in
an environmentally-friendly manner.
Discharge the battery pack in the power tool before
disposal. Prevent the contacts from short-circuiting
(e.g. by protecting them with adhesive tape).
f

12. Technical Data

Explanatory notes on the specifications on page 3.
Subject to change in accordance with technical
progress.
U
=
Voltage of battery pack
m
=
Weight (with smallest battery pack)
H
=
Total stroke
F
=
Setting force
D
=
Rivet diameter for steel rivets
steel
D
=
Rivet diameter for stainless steel rivets
ssteel
D
=
Rivet diameter for aluminium rivets
alu
Measured values determined in conformity with EN
62841.
Permitted ambient temperature during operation: -
20 °C bis 50 °C (limited performance with
temperatures below 0 °C). Permitted ambient
temperature for storage: 0 °C to 30 °C
direct current
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
Explanatory notes on the specifications on page 2.