Three (3)Thermostats: differential of 2° between each thermostat : example wood = 24°C, pellets = 22°C, electric = 20°C
1- Save the wanted temperature degree on the thermostat for wood heating
2- Save the temperature degree for pellet heating at 2° less than the wood heating degree.
3- Save the temperature degree for the electric element at 2° less than the pellet heating degree.
See operating notes in the One (1) thermostat section.
SELECTION OF TYPES OF HEATING (SWITCHES)
1- Position the central switch according to the type of heating wanted.
The furnace is automatically in PILOT mode.
The «RESET» DOOR switch is an automatic release button.
2- Position the tab of the mechanic fan limit on AUTO.
«MAN» can be used to operate (non-stop) the G10 fan in summer period (summer speed)
ALL COMPONENTS MUST BE PROPERLY CONNECTED FOR THE OPERATION OF WOOD OR WOOD-PELLET HEATING
AND THAT EVEN IF YOU WISH TO USE ONLY WOOD HEATING.
Proceed with the filling of wood as specified in the user's manual.
3-
4-
Close the furnace door.
The pre-programming of the furnace will start the pellet heating FIVE (5) HOURS after EACH opening / closing of the
furnace door.
Or :
5-
After closing the door, keep upwards about TEN (10) SECONDS the «RESET» DOOR switch. The pellet heating
ignition cycle will start according to the temperature demand saved in the thermostat.
ALARMS HELP GUIDE:
NOTE THAT SOME ALARMS ARE AVAILABLE ONLY WITH THE TOUCHSCREEN
ALARM BURNER LOW POWER
The power of the ember burner is too low for proper operation of your furnace.
1- Make sure the « BURNER » plug is firmly in place and that the wire is not damaged.
If this alarm persists, contact L.S. Bilodeau technical support at 418-484-2013.
ALARM BURNER LOW PRESSURE
The pressure of the ember burner is to low for proper functioning of your furnace.
1-
Check that the "BURNER" connector is properly in place and the wire is not damaged.
2-
Check under the pressure sensor that the small tube is well connected to the "P1 +" position and the other end well
connected under the burner.