Étape 62:
Keep a sufficient length for the connection and
place the excess wire in the wire-cover* of the
ventilation box.
*Wire-cover see step 90
SWITCH PANEL INSTALLATION
Step 64:
Screw with the supplied screws the switch
plate (N) on the front, top right of the furnace.
(Under the top hopper
mounting plate).
CHIMNEY CONNECTION AND INSTALLATION OF PLENUMS
Step 66:
Connect the chimney as described on pages 43 and 46 of the owner's manual. The furnace should be located as close as possible to
the base of the chimney so that the chimney connection is as short and straight as possible. Comply with current standards and
codes (manual page 43: Compliance with standards and codes).
Step 67:
Install hot and cold air plenums as described in the manual on pages 44 and 47.
INSTALLATION OF FAN LIMITS: MECHANIC in 1
Plenum
edge
Front side
furnace
L.S. Bilodeau inc.
Étape 63:
Connect the "Molex" of the door switch to the indicated
location "INTERRUPTEUR PORTE / DOOR SWITCH" on the
vent box.
Electronic Fan Limit Mecanic Fan Limit
Drill 1/2"
hole
6-1/2"
11" center hole from edge
plenum front furnace
FURNACE RIGHT SIDE ILLUSTRATED
CHOICE OF DRILLING THE PLENUM ON THE LEFT OR
RIGHT SIDE OF FURNACE. THE MECHANICAL LIMITER
IS AT 9-1 / 8 "FROM THE PLENUM EDGE (FRONT
FURNACE), FOR EITHER RIGHT OR LEFT SIDE.
SEE FOLLOWING STEPS
281 Route 108 Est, Saint-Éphrem-de-Beauce, Quebec G0M 1R0
Tel.: 418 484-2013 ▪ Fax: 418 484-2014 ▪
Step 65:
Secure the wire of the switch as in step 61 to the
top of the box and place the excess wire in the
wire cover * (keep enough length) and connect to
the ventilation box at the indicated location.
st
and ELECTRONIC in 2
PLÉNUM
Drill 1" hole
5-1/8"
www.lsbilodeau.com