Assa Abloy KESO KEK Genie Knauf Manuel D'utilisateur page 10

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

KESO KEK Genie Knob
2.3.2
Management of a KESO KEK Genie PC System
If you are operating a system of the KESO KEK Genie PC version, it is strongly recommended that
you take part in our training for the KESO KEK Genie. In these seminars you will be both trained
on our KESO management software and made aware of the entire philosophy that lies behind
the mechatronic locking system.
2.4
End of battery life detection
Every time a key is inserted, the battery voltage is measured automatically. The system reports, in
three steps, when the battery performance decreases. Please inform the end user that the person
responsible for the system must be informed of each of these detection characteristics. This
guarantees that the battery is changed in time.
2.4.1
First detection characteristic shortly before end of battery life
The key must be inserted twice before the key can be turned.
Measures and behavior
At this sign, the battery should be changed by a specialist at the next opportunity. If the cylinder
is subjected to extreme temperatures, it is advisable to immediately change the battery.
2.4.2
Second detection characteristic immediately before end of battery life
The key must be inserted four times, before the key can be turned.
Measures and behavior
At this sign, it is COMPULSORY that the battery be changed IMMEDIATELY by a specialist. If the
battery is not changed immediately, the result may be that the KESO KEK Genie knob cylinder
only can be operated mechanically from the inside.
2.4.3
Third detection characteristic at the end of battery life
The cylinder reverts to the pre-set position, either open without current or closed without
current. If, when ordering, no specifications are made about the state at the end of the battery
life, the KESO KEK Genie cylinder will be delivered in the open without current state at the end of
the battery life. In a PC version, the state at the end of battery life can be changed at any time in
the KESO KESO management software
Measures and behavior
If the pre-set position is set to <State at end of current - closed>, the cylinder can only be
operated from the mechanical side. If the pre-set position is set to <State at end of current -
open >, the actuator is switched off at the end of battery life and the KESO KEK Genie cylinder
only checks the mechanical functions.
KESO AG 05/2009
Subject to change without notice
Page 10 from 24 pages