Inlet Parameters
Air Quality
Pressure
Temperature
Purity
Port Connections
Air Inlet
N
Outlet to Buffer
2
N
Inlet from Buffer
2
N
Outlet
2
Electrical Parameters
(1)
Generator Supply
(2)
Generator Power
(3)
Fuse
(4)
Max Dryer Power
(1) The generator does not require adjustment when connecting to 115v and 230v
electrical supplies.
(2) The power rating specified is for the generator alone and does not take in to
account any pre-treatment dryer connected to the dryer supply terminals of the
generator.
(3) (Anti Surge (T), 250v, 5 x 20mm HBC, Breaking Capacity 1500A @ 250v, IEC 60127,
UL R/C Fuse).
(4) The dryer is fed directly from the generator supply.

2.2 Approvals and Compliance

2.2.1 Approvals

Directives
97/23/EC: Pressure Equipment Directive
2004/108/EC: Electromagnetic Compatibility Directive
2006/95/EC: Low Voltage Directive
Safety and Electromagnetic Compatibility Standards
This equipment has been tested and complies with the following European Standards:
EN 61326-1:2013 EMC - Electrical equipment for measurement, control and laboratory use. EMC requirements.
(Equipment tested to: Emissions - Light, Immunity - Heavy)
BS EN 61000-3-2:2006+A2:2009 Electromagnetic compatibility (EMC). Limits for harmonic current emissions (equipment input current = 16 A
per phase)
BS EN 61000-3-3:2013 Electromagnetic compatibility (EMC). Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-
voltage supply systems, for equipment with rated current = 16 A per phase and not subject to conditional connection.
BS EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use. General requirements
General
Designed generally in accordance with ASME VIII DIVISION 1: EDITION 2010 2011a Addenda

2.2.2 Compliance

This gas generator is compliant with FDA and European Pharmacopeia Regulations for use as a medical gas generator.
ISO 8573-1: 2010 Class 2.2.2
(2.2.1 with high oil vapour content)
5 –13 bar g (72.5 - 188.5) psi g
o
o
5 – 50
C (41 – 122
F)
20.948%
(wrt O2)
0.0314%
(wrt CO2)
G1"
G1"
G1/2"
G1/2"
100 - 240 +/- 10% Vac 50/60Hz
55 W
3.15 A
100W
Environmental Parameters
Ambient Temperature
Humidity
IP Rating
Pollution Degree
Installation Category
Altitude
Noise
Packed Weights and Dimensions
Height (H)
Model
mm
ins
CN2-20P
CN2-25P
725.5
28.6
CN2-35P
CN2-45P
1994
CN2-55P
825.5
32.5
CN2-60P
828.5
32.6
CN2-65P
CN2-75P
831.5
32.7
CN2-80P
o
50% @ 40
C (80% @
IP20 / NEMA 1
Width (W)
Depth (D)
mm
ins
mm
ins
1090
42.9
398.4
1260
49.6
495.4 1092.1
1430
56.3
580.4 1279.6
1600
63.0
686.4 1513.3
78.5
1770
69.7
782.4 1724.9
1935
76.2
897.4 1978.4
2100
82.7
997.4 2198.9
2275
89.6 1093.4 2410.5
2445
96.3 1186.4 2615.6
o
5 – 50
C
o
(41 – 122
F)
d
o
31
C)
MAX
2
II
< 2000 m
(6562 ft)
<80 dB (A)
Weight
Kg
lbs
878.3
7