4.4.1 Hour Meters

There are four hour meters available for viewing:
1.1
1.1
Hours run
Hours run
5234h
5234h
1.2
1.2
Service due at
Service due at
8000h
8000h
1.3
1.3
Hours economy
Hours economy
25h
25h
1.4
1.4
Hours EST
Hours EST

4.4.2 Fault Log

The fault log menu allows the user to access the 10 most recent fault messages.
2.1
2.1
Fault 1: Active
Fault 1: Active
C1 at 5234h
C1 at 5234h
Refer to "Fault Codes" on page 27 for a full listing of fault codes.

4.4.3 Customer Settings

To prevent unauthorised access to the configurable parameters, the customers setting menu has optional password protection. This is disabled
by default and can be enabled in menu 3.1
To gain access in to this menu, when password has been enabled:
Press and hold both the
password prompt as shown.
The flashing cursor will be positioned over the first digit. Using the
code and press
. The cursor will move to the next digit.
Repeat the process and enter the following password 1 2 1 _ _ . When the password has been entered correctly the Hour Meters menu will be
displayed. Use the
key to navigate to page 3 "Customer Settings" menu and press
3.1
3.1
Password enable
Password enable
3.2
3.2
Oxygen alarm
Oxygen alarm
over-ride
over-ride
3.3 Calibrate outlet
3.3 Calibrate outlet
sensor =
sensor =
3.4 Calibrate EST
3.4 Calibrate EST
sensor
sensor
=
=
3.5 Pressure reading
3.5 Pressure reading
3.6
3.6
Pressure units
Pressure units
20
The time in hours that the generator has been producing gas.
The time in operating hours that the generator can produce gas before a service is required.
The time in hours that the generator has been operating in Economy mode.
The time in hours that the generator has been operating in EST mode.
4h
4h
Each fault is represented by a fault code and is displayed along with the run hours at which the fault occurred. If a
fault is active the fault code displayed will flash. Any faults that are active when the power is switched off, and are
still active when the power is re-applied, will cause a new entry to be added into the fault log.
and
keys for approximately 5 seconds until the menu changes to the
When enabled the end user is required to enter a password to gain access to the customer configuration
menu.
= 0
= 0
0 = Disabled, 1 = Enabled
When enabled the Oxygen alarm is over-ridden.
0 = Over-ride disabled, 1 = Override Enabled [OVR]
=0
=0
Outlet oxygen sensor calibration menu.
5.00%
5.00%
Refer to section 4.8 for details on calibration.
EST oxygen sensor calibration menu.
5.00%
5.00%
Refer to section 4.8 for details on calibration.
Displays the outlet pressure in real time.
= 8Bar
= 8Bar
Also used for the inlet pressure set up.
Sets the units of measure for the outlet pressure.
Units available are Bar / Psi / Mpa
= Bar
= Bar
key change the first digit of the
.
1 1 21