This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered usage)
Parameter
USEPA
MCL
Chlorine
T & O
Particulate**
Parameter
USEPA
MCL
Turbidity
0.5 NTU
≥ 99.95% Reduction
Cysts
≥ 99% Reduction
Asbestos
Lead at pH 6.5
0.015 mg/L
Lead at pH 8.5
0.015 mg/L
Mercury at pH 6.5
0.002 mg/L
Mercury at pH 8.5
0.002 mg/L
Alachlor
0.002 mg/L
Lindane
0.0002 mg/L
2,4-D
0.070 mg/L
Toxaphene
0.003 mg/L
Benzene
0.005 mg/L
Carbofuran
0.040 mg/L
1,4 dichlorobenzene
0.075 mg/L
Atrazine
0.003 mg/L
* Tested using a flow rate of 0.50 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbidity units
Operating Specifications
Capacity: certified for up to 300 gallons (1135 l); up to six months for models without a replacement filter indicator light;
up to one year for models with a replacement filter indicator light
Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock
Temperature: 33–100ºF (0.6–38ºC)
Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance Requirements
Flush new cartridge at full flow for 3 minutes to purge out trapped air.
Replace cartridge when the indicator light flashes or water flow rate is
reduced on non-indicator units.
Special Notices
Installation instructions, parts and service availability, and standard warranty
are included with the product when shipped.
This drinking water system must be maintained according to manufacturer's
instructions, including replacement of filter cartridges.
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system. Systems certified for cyst
reduction may be used on disinfected water that may contain filterable cysts.
The contaminants or other substances removed or reduced by this water
treatment system are not necessarily in your water.
Check for compliance with the state and local laws and regulations.
Note that while the testing was performed under standard laboratory conditions,
actual performance may vary. Systems must be installed and operated in
accordance with manufacturer's recommended procedures and guidelines.
System Tested and Certified by NSF International against ANSI/NSF Standard 42 & 53
for the reduction of:
Standard No. 42: Aesthetic Effects
Chemical Unit
Chlorine Taste and Odor
Mechanical Filtration Unit
Particulate Reduction, Class I

Performance Data Sheet

SmartWater Filtration System
Standard No. 42: Aesthetic Effects
Influent
Challenge Concentration
2.0 mg/L + 10%
≥ 10,000 particles/mL
6,400,000 #/mL
Standard No. 53: Health Effects
Influent
Challenge Concentration
11 + 1 NTU***
Minimum 50,000 L
10
7
to 10
8
fibers/L; > 10µm
0.15 mg/L + 10%
0.15 mg/L + 10%
0.006 mg/L + 10%
0.006 mg/L + 10%
0.04 mg/L + 10%
0.002 mg/L + 10%
0.210 mg/L + 10%
0.015 mg/L + 10%
0.015 mg/L + 10%
0.080 mg/L + 10%
0.225 mg/L + 10%
0.009 mg/L + 10%
Standard No. 53: Health Effects
Chemical Reduction Unit
Alachlor and Atrazine Reduction
Benzene and Carbofuran Reduction
1,4 dichlorobenzene and 2,4-D Reduction
Lead and Lindane Reduction
Mercury and Toxaphene Reduction
Mechanical Filtration Unit
Turbidity Reduction
Cyst and Asbestos Reduction
MWF Cartridge
Influent
Effluent
Average
Average
1.96 mg/L
0.06 mg/L
58,833 #/mL
Influent
Effluent
Average
Average
10.5 NTU
0.14 NTU
118,750 #/L
< 1 #/L
57 MF/L
0.996 MF/L
0.1567 mg/L < 0.001 mg/L
0.1433 mg/L < 0.001 mg/L
0.0059 mg/L 0.000350 mg/L 0.0007 mg/L
0.0057 mg/L 0.000325 mg/L 0.0006 mg/L
0.0367 mg/L 0.00023 mg/L
0.0020 mg/L < 0.00002 mg/L < 0.00002 mg/L
0.2033 mg/L 0.00337 mg/L 0.011000 mg/L
0.0160 mg/L 0.00100 mg/L 0.001000 mg/L
0.0145 mg/L 0.000500 mg/L 0.000500 mg/L
0.0830 mg/L 0.001000 mg/L 0.001000 mg/L
0.2283 mg/L 0.000500 mg/L 0.000500 mg/L
0.0087 mg/L < 0.0005 mg/L < 0.0005 mg/L
NSF
Manufactured for: General Electric Company, Louisville, KY 40225
EPA EST. No. 070595-MN-001
% Reduction
Maximum
Average
Minimum
0.11 mg/L
96.77%
150,000 #/mL
99.14%
% Reduction
Maximum
Average
Minimum
0.28 NTU
98.54%
97.20%
4 #/L
> 99.99%
> 99.99%
< 1 MF/L
99.60%
99.39%
< 0.001 mg/L
99.36%
99.29%
< 0.001 mg/L
99.30%
99.29%
94.70%
87.50%
93.20%
89.29%
0.0004 mg/L
99.34%
98.67%
99.00%
98.95%
98.32%
94.50%
93.44%
91.67%
96.51%
95.83%
98.78%
98.65%
99.78%
99.77%
94.22%
93.33%
State of California
Department of Health Services
Water Treatment Device
Certificate Number
05 -
1698
Date Issued: February 2, 2005
Trademark/Model Designation
MWF
Manufacturer: General Electric Company
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Microbiological Contaminants and Turbidity
Cysts
Turbidity
Organic Contaminants
Alachlor
Atrazine
Benzene
Carbofuran
Lindane
Mercury
Toxaphene
1,4-dichlorobenzene
2,4-D
Rated Service Capacity:
300 gal
Conditions of Certification:
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified for
cyst reduction may be used on disinfected waters that may contain filterable cysts.
®
Min. Required
Reduction
94.74%
> 50%
≥ 85%
97.97%
Min. Required
Reduction
0.5 NTU
≥ 99.95%
≥ 99%
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.04 mg/L
0.075 mg/L
0.003 mg/L
Replacement Elements
MWF
Inorganic/Radiological Contaminants
Asbestos
Lead
Mercury
Rated Service Flow:
0.5 gpm