HiSewlift 3-I35 (Fig. 3)
1 - Bushing
2 - Elbow
3 - 3-outlet bushing
4 - Plug
5 - Fixation strip (x2)
6 - Screw (x2)
7 - Foam foot (x4)
8 - Screw clamp (x2 for each part number)

6 Description and function

6.1 Description of the product (see figures)
Compact lifting unit for domestic wastewater which cannot flow naturally into the
sewer or natural outfall.
6.2 Function of the product
Automatic collection and drainage of domestic wastewater.

7 Installation and connections

DANGER! Risk of fatal injury!
Any improper installation or improper electrical connection may have fatal
consequences. Danger from electrical current must be eliminated.
• Installation and electrical connection work must always be carried out by
qualified technical personnel and in accordance with the applicable regulations.
• Comply with accident prevention regulations.
• Follow the instructions of the local energy supply company!
• The comminutor must be in the same room as the toilet and the other sanitary
installations connected.
• The device must be easily accessible for inspection, maintenance and repair.
• The installation and functioning of your device must comply with local regulations
and the standard EN 12056-4.
• To make the most of the latest developments for noise reduction included in the
design of this device, it is important to:
- Install the tank so that it is not touching the walls of the room if possible,
- Position the tank on a completely flat surface so as not to impair the function of
the anti-vibration supports,
- Secure the drainage piping correctly, avoiding distances greater than one metre
between fixation points.
• HiSewlift 3-15 and HiSewlift 3-35 (Fig. 4 and 6)
• HiSewlift 3-I35 (Fig. 5 and 6)