Wilo HiSewlift 3 Notice De Montage Et De Mise En Service page 29

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
8 Commissioning
• Flush the toilet several times. The toilet bowl outlet must be free of leaks.
• Switch on the power supply to the system.
• Check that there are no leaks at the connections to the sanitary devices
connected to the lifting unit.
• Check that the current consumed is less than or equal to the rated current.
9 Maintenance
All maintenance work must be carried out by authorised and qualified
personnel!
WARNING! Risk of electric shock!
Danger from electrical current must be eliminated.
Before any electrical work, the unit must be DE-ENERGISE (switched off) and
protected against unauthorised restarting.
In the event of prolonged absence, be sure to cut off the mains water supply to
the house and protect the installation from freezing.
Cleaning/descaling
To descale and clean the lifting unit, regularly use a descaling agent specially
designed to remove scale without damaging the internal components of your
device.
WILO SE
English
29

Publicité

Table des Matières
loading

Table des Matières