Handling

2.1 Transport

2.2 Storage

2.3 Unpacking

3

Scope of delivery and options

3.1 Scope of delivery

3.2 Options

14
CAUTION:
If the measures described in the following are not strictly observed
material damage may be caused.
Hint
A hint contains additional information on the action or instruction described.
Lift the cooling unit using either the housing or the supporting frame.
Transport the cooling unit only in condition of usage.
Prior to transport remove the cooling unit and pack it separately if the complete switch
cabinet is to be transported.
Failure to observe these instructions will render the warranty provisions null and void.
Never expose cooling units to temperatures exceeding +70 °C during storage.
Store cooling unit only in condition of usage.
Failure to observe these instructions will render the warranty provisions null and void.
Prior to and during unpacking make a visual inspection of the cooling unit to see whe-
ther any damage has occurred during transport. Especially pay attention to loose parts,
dents, scratches, visible loss of oil etc.
Any damage must be reported immediately to the forwarding agent (follow the instruc-
tions in "Rules for Damage Claims"). Moreover, the latest edition of the "General Con-
ditions for Supplies and Services" issued by the ZVEI ( Central Association for the
German Electrotechnical Industry") shall apply.
Before disposing of packing material ensure that it does not contain any loose com-
ponents.
Do not place the unit directly on the floor as otherwise the condensate drainage con-
nection may be damaged.
Burr caused by production may be present on the metal edges of the unit. Always wear
protective gloves when carrying out maintenance work and installation.
In case of a warranty claim exact details on the fault (photograph, if possible) and the
indication of type and serial number of the cooling unit are required.
The Scope of delivery includes:
– cooling unit,
– fastening material,
– hose and clamp for condensate drainage,
– sealing for the gap between switch cabinet and cooling unit,
– special accessories, if applicable.
The following parts may be ordered separately:
– built-in reservoir, for sunk-in installation (only for side panel cooling unit);
– door contact switch to switch off the cooling unit as soon as the door of the switch
cabinets opens;
– further parts upon request or according to catalogue.