Safety Devices - livin flame Stavanger 6 Mode D'emploi Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety devices

Pressure
switch:
monitors
depression in the smoke duct.
It is designed to shut down
the pellet feed screw in the
event of an obstructed flue or
significant back-pressure in the
presence of wind. At the time
of the pressure switch will show
"A LA R- D E P- FAIL".
Electrical safety: the stove is
protected against violent surges
of current (ex. lightnings) by the
main fuse 4 A which is located
on the control panel at the rear
of the thermostove. Other fuses
to protect the electronic boards
are to be found on the boards
themselves.
Tampering with the safety devices is prohibited. It is only after eliminating the
cause which gave rise to the intervention of the safety system, that it is possi-
ble to relight the stove and thus reset the automatic operation of the sensor.
To understand which anomaly has occurred, consult this manual at paragraph
relating to alarms which explains what to do based on the alarm message the
stove display.
Reduction
motor:
if
motor stops, the thermostove
continues to function until the
flame goes out for lack of fuel,
and until It has cooled down to
the minimum level.
RESTART
PELLET
Pellets temperature safety: In
the rare event there is a too high
temperature in the tank,
the thermostat for pellets safety
with
manual
reset
creates
an
alarm
"A LAR -S IC - F AIL "
stopping the pellet boiler stove.
You need to reset the system
working on the device placed
on the back of the thermostove.
Flue gas temperature sensor:
the
thermocouple that measures
the temperature of the fumes
while keeping the operation or
shuts the thermostove when
the flue gas temperature drops
below the preset value.
Room thermostat: the room
thermostat detects the present
temperature in the room. When
it detects the set temperature
on the display, the stove will go
into operation in ECO ie hold
function to save fuel.
The room thermostat should
be spread so as not to be
conditioned by the temperature
of the body stove.