Operating Specifications; Special Notices - GE PSB42LGRWV Manuel D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered usage)
Parameter
USEPA
MCL
Chlorine
T & O
Particulate**
Parameter
USEPA
Turbidity
1 NTU***
Cysts
99.95% Reduction
Lead at pH 6.5
15 ppb
Lead at pH 8.5
15 ppb
Lindane
0.0002 ppm
Atrazine
0.003 ppm
2,4-D
0.100 ppm
Asbestos
* Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 20° ± 2.5°C
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbidity units

Operating Specifications

Capacity: certified for up to 500 gallons (1135 l); up to twelve months for all models
Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock
Temperature: 33–100ºF (0.6–38ºC)
Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance Requirements
Flush new cartridge at full flow for 3 minutes to purge out trapped air.
Replace cartridge when flow becomes too slow.

Special Notices

Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
This drinking water system must be maintained according to manufacturer's instructions, including replacement of filter
cartridges.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your
water.
Check for compliance with the state and local laws and regulations.
Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems
must be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
System Tested and Certified by NSF International against ANSI/NSF Standard 42 & 53 for
the reduction of:
Standard No. 42: Aesthetic Effects
Chemical Unit
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particulate Reduction, Class I
Manufactured for: General Electric Company, Louisville, KY 40225
42
SmartWater Filtration System
Influent
Challenge Concentration
2.0 mg/L + 10%
at least 10,000 particles/mL
Influent
MCL
Challenge Concentration
11 + 1 NTU***
Minimum 50,000 L
0.15 mg/L + 10%
0.15 mg/L + 10%
0.002 mg/L + 10%
0.009 mg/L + 10%
0.210 mg/L + 10%
99%
10
to 10
fibers/L;
7
8
fibers greater than
10 micrometers in length
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead and Atrazine Reduction
Lindane and 2,4-D Reduction
Mechanical Filtration Unit
Turbidity Reduction
Cyst and Asbestos Reduction
Performance Data Sheet
GWF / HWF Cartridge
Standard No. 42: Aesthetic Effects
Effluent
Average
0.02 ppm
3,978
Standard No. 53: Health Effects
Effluent
Average
0.07 NTU
26
1 ppb
1.8 ppb
0.00005 ppm
0.002 ppm
0.042 ppm
0.32 MFL/ml
% Reduction
Maximum
Average
0.05 ppm
98.90%
7,800
98.00%
% Reduction
Maximum
Average
Minimum
0.1 NTU
99.71%
55
99.97%
1 ppb
99.37%
4.3 ppb
98.8%
0.00005 ppm
91.93%
0.003 ppm
76.19%
0.090 ppm
84.89%
1.2 MFL/ml
99.95%
NSF
®
Min. Required
Minimum
Reduction
97.37%
> 50%
96.10%
> 85%
Min. Required
Reduction
99.59%
0.5 NTU
99.95%
> 99.95%
99.37%
0.010 mg/L
97.13%
0.010 mg/L
91.93%
0.0002 mg/L
64.28%
0.003 mg/L
67.63%
0.07 mg/L
99.82%
99%