13. Place the new PRIME/SPRAY valve knob over the cam
with the pointer on the knob (fig. 22, item 1) as close to
the 09:00 position as possible. Make sure the knob is
pushed completely onto to the cam (the knob should
cover the cam completely).
1
09:00
Figure 23 below shows the rear view of the
i
relief valve knob. The knob is designed to
allow 90º of movement between the SPRAY and
PRIME positions.
The inside of the knob has a 90º opening (fig.
23, item 1) in its circumference where the tab of
the cam (2) should be positioned to allow this
movement.
When placing the knob with the arrow in the
09:00 position, make sure that the tab on the
cam is within the 90º opening on the inside of
the knob. Then, make sure the knob is at the
end of its movement in the clockwise direction
(this is the SPRAY position) before continuing
with this procedure.
1
14. Slowly turn the knob counterclockwise until the bottom
of the knob moves out to where it is flush with the
bottom of the cam (approximately 5–7º).
15. Place the retaining clip over the stem of the stem/ball
assembly where the stem passes through the recessed
portion of the knob.
16. Using a 5/16" (8 mm) nut driver, push the clip into the
recessed portion of the knob with steady, even pressure
until it stops.
Do not hammer or wiggle the clip into position.
It will damage the clip.
Attention
PowrLiner 550
12:00
1
SPRAY
2
GB
17. Turn the relief valve knob to the PRIME (
18. Start up the sprayer and run water through the system
to check for leaks. If there are no leaks, the sprayer is
ready to use.
19
Maintenance
k
) position.