INSTRUCTIONS FOR USE
achieves highest position number, then it again gets position with lowest sequential number.
Button for editing the program name.
Press and hold the button for ca 2 seconds. Alphanumeric keyboard is displayed by means of which the
text can be edited. Maximum length of the text is 20 characters.
Button for the selection of transmission ratio of the handpiece.
Press the button to display a „pop-up menu" with transmission ratio options:
Press the respective button to select the desired transmission ratio or cancel the selection of transmission ratio by
pressing the button „ESC". If you want to save the new value of the transmission ratio permanently into the memory, first
press the button of saving into the memory
change in the colour of the icon
Button for setting the motor torque.
Press the button to start the setting mode in which the buttons whose values can be changed are displayed
in red. Change the parameter value by means of the buttons +/- .
The new value is saved temporarily (until the change of the program number) by pressing the button of
the parameter being set again or permanently into the program by means of the button
in the mode ENDODONTIC.
Button to active / deactivate the peristaltic pump
Press the button to activate -
pump is started together with the instrument when the lever / pedal of the foot controller has been moved.
Button for setting the flowrate and forced starting of the peristaltic pump.
The button is divided into two parts and it is active only if the peristaltic pump has been activated. To set
the flowrate of the media through the pump, press the right part of the button -
is started, in which the buttons whose values can be changed are displayed in red. Change the
parameters by means of the buttons +/. The new value is saved temporarily (until the change of the program number)
by pressing the button of the parameter being set again or permanently into the program by means of the button
.
The new value can be entered also directly via numerical keyboard after pressing the button
the left part -
to start the forced running of the peristaltic pump with the lever / pedal of the foot controller moved
without the motor started. The condition remains until turned off by repeated pressing the button
control forced run of peristaltic pump by side button of foot controller by assigning function Chipblower on this side
button.
Button to turn the instrument light on / off.
Press the button to turn the instrument illumination on -
Button to change the direction of the motor rotation.
Press the button to change the direction of the motor rotation -
position of the lever / pedal of the foot controller.
Button to change the operation mode of the pedal / lever of the foot controller.
The button is active only if the output control mode is enabled. It indicates the discrete mode of the pedal, i.e.
after pressing the foot controller pedal / lever, the controlled quantity jumps to maximum set values and does
not change any more with the pedal position. By pressing the button the following is displayed:
UM_EN_TYGI350B_2018-09_ver1.0
. The new condition of saving the data into the memory is indicated by
. To cancel the condition, press the button again.
/ deactivate -
starting the peristaltic pump. If activated, the peristaltic
/ off -
.
. The button is active only at the rest
TYGI 350 B
. The button is active only
. The setting mode
40%
Pres the button in
. It is possible to
32 / 49