Service And Repairs - Hitachi NR 90AD Manuel D'instructions Et De Sécurité

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
2. Storing
○ When not in use for an extended period, apply a thin
coat of the lubricant to the steel parts to avoid rust.
○ Do not store the Nailer in a cold weather environment.
Keep the Nailer in a warm area.
○ When not in use, the Nailer should be stored in a
warm and dry place.
Keep out of reach children.
3. WARNING LABEL
Change the WARNING LABEL if missing or
damaged.
A new WARNING LABEL is available from a Hitachi
authorized service center.
4. Maintenance chart (See page 18)
5. Operator troubleshooting (See page 19)
6. Service parts list
A: Item No.
B: Code No.
C: No. Used
D: Remarks
Maintenance chart
ACTION
Drain air line fi lter daily.
Keep lubricator fi lled.
Clean fi lter element — then blow air
through fi lter in direction opposite to
normal fl ow.
Clean magazine and feeder
mechanism.
Keep push lever working properly.
Lubricate the Nailer after nailing.
Drain air compressor.
18
● Repair, modifi cation and inspection of Hitachi
MODIFICATIONS

SERVICE AND REPAIRS

Warning Label
All quality Nailers will eventually require servicing or
replacement of parts because of wear from normal use.
NOTE
WHY
Prevent accumulation of moisture
and dirt.
Keep the Nailer lubricated.
Prevent clogging of fi lter with dirt.
Prevent a jam.
Promote operator safety and effi cient
Nailer operation.
Extend the Nailer life.
Keep the Nailer operated properly.
CAUTION
Power Tools must be carried out by a Hitachi
Authorized Service Center.
This Parts List will be helpful if presented with
the tool to the Hitachi Authorized Service Center
when requesting repair or other maintenance. In
the operation and maintenance of power tools,
the safety regulations and standards prescribed
in each country must be observed.
Hitachi Power Tools are constantly being improved
and modifi ed to incorporate the latest technological
advancements.
Accordingly, some parts (i.e. code numbers and/or
design) may be changed without prior notice.
WARNING
● Only service personnel trained by Hitachi,
distributor or employer shall repair the Nailer.
● Use only parts supplied or recommended by
Hitachi for repair.
Specifi cations are subject to change without any
obligation on the part of HITACHI.
Open manual petcock.
Fill with Hitachi pneumatic tool
lubricant.
Follow manufacturer's instructions.
Blow clean daily.
Blow clean daily.
Supply 5 – 10 drops of lubricant into
the Nailer.
Open petcock on air
HOW

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Nr 90ad s1Nr 90aeNr 90ae s1

Table des Matières