1 DISCONNECT AIR HOSE FROM NAILER.
2 If nails are driven too deep, turn the adjuster to the
shallow side.
2
Too Deep
NOTE: The information contained in this Manual is designed to assist you in the safe maintenance of the Nailer.
Some illustrations in this Manual may show details or attachments that diff er from those on your own Nailer.

MAINTENANCE AND INSPECTION

Read section titled "SAFETY" (pages 4 – 7).
● Disconnect air hose and remove all nails
from Nailer when:
1) doing maintenance and inspection; and
2) clearing a jam.
1. Inspecting the magazine
1 DISCONNECT AIR HOSE.
2 Clean the magazine. Remove paper chips or wooden
chips which may have accumulated in the magazine.
Lubricate it with Hitachi pneumatic tool lubricant.
Adjuster
15
Disconnect air hose
Turn Adjuster
Flush
MAINTENANCE
WARNING
If nails are driven too shallow, turn the adjuster to the deep
side.
2
Too Shallow
3 Stop turning the adjuster when a suitable position is
reached for a nailing test.
4 Connect the air hose.
ALWAYS WEAR EYE PROTECTOR.
Perform a nailing test.
5 DISCONNECT AIR HOSE FROM NAILER.
6 Choose a suitable position for the adjuster.
Cloth
CAUTION
● Check that the nail feeder slides smoothly by
pulling it with fi nger.
If not smooth, nails can be driven at an irregular
angle and hurt someone.
English
Turn Adjuster
Flush
1
Disconnect
air hose
17